Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Mar 4;6(5):533-539.
doi: 10.22603/ssrr.2021-0197. eCollection 2022 Sep 27.

Novel Modular Spine Blocks Affect the Lumbar Spine on Finite Element Analysis

Affiliations

Novel Modular Spine Blocks Affect the Lumbar Spine on Finite Element Analysis

Jui-Yang Hsieh et al. Spine Surg Relat Res. .

Abstract

Introduction: There are various surgical interventions to manage osteoporotic vertebral compression fracture. Modular spine block (MSB) is a novel intravertebral fixator that can be assembled. This study aimed to quantitatively investigate the force distribution in vertebrae with the various structural designs and implantation methods by finite element analysis (FEA).

Methods: A three-dimensional nonlinear FEA of the L3 implanted with MSB was constructed. Different structural designs (solid vs. hollow) and implantation methods (three-layered vs. six-layered and unilateral vs. bilateral) were studied. The model was preloaded to 150 N-m before the effects of flexion, extension, torsion, and lateral bending were analyzed at the controlled ranges of motion of 20°, 15°, 8°, and 20°, respectively. The resultant intervertebral range of motion (ROM) and disk stress as well as intravertebral force distribution were analyzed at the adjacent segments.

Results: The different layers of MSB provided similar stability at the adjacent segments regarding the intervertebral ROM and disk stress. Under stress tests, the force of the solid MSB was shown to be evenly distributed within the vertebrae. The maximum stress value of the unilaterally three-layered hollow MSB was generally lower than that of the bilaterally six-layered solid MSB.

Conclusions: The MSB has little stress shielding effect on the intervertebral ROM and creates no additional loading to the adjacent disks. The surgeon can choose the appropriate numbers of MSB to fix vertebrae without worrying about poly(methyl methacrylate) extravasation, implant failure, or adjacent segment disease.

Keywords: adjacent segment disease; finite element analysis; intravertebral fixation; modular spine block; osteoporotic vertebral compression fracture.

PubMed Disclaimer

Conflict of interest statement

Conflicts of Interest: The authors declare that there are no relevant conflicts of interest.

Figures

Figure 1.
Figure 1.
Top (upper) and lateral views (lower) of the seven lumbar spine finite element models.
Figure 2.
Figure 2.
Solid (A) and hollow MSB (B). The isometric view is shown on the left, while the lateral and top views are shown in the middle and right, respectively (unit: mm).
Figure 3.
Figure 3.
Intravertebral force distribution under flexion (A) and extension (B) in L3 (Unit: Pa).

References

    1. Chapman J, Smith JS, Kopjar B, et al. The AOSpine North America Geriatric Odontoid Fracture Mortality Study: a retrospective review of mortality outcomes for operative versus nonoperative treatment of 322 patients with long-term follow-up. Spine. 2013;38(13):1098-4. - PMC - PubMed
    1. Kohno M, Iwamura Y, Inasaka R, et al. Surgical intervention for osteoporotic vertebral burst fractures in middle-low lumbar spine with special reference to postoperative complications affecting surgical outcomes. Neurol Med Chir. 2019;59(3):98-105. - PMC - PubMed
    1. Chen HY, Chen CL, Chen WL. Repeated adjacent segment diseases and fractures in osteoporotic patients: a case report. Ther Clin Risk Manag. 2016;12:1145-50. - PMC - PubMed
    1. Galibert P, Deramond H, Rosat P, et al. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie. 1987;33(2):166-8. - PubMed
    1. Flors L, Lonjedo E, Leiva-Salinas C, et al. Vesselplasty: a new technical approach to treat symptomatic vertebral compression fractures. AJR Am J Roentgenol. 2009;193(1):218-26. - PubMed

LinkOut - more resources