Dynamic parameters for fluid responsiveness in mechanically ventilated children: A systematic review
- PMID: 36353262
- PMCID: PMC9638161
- DOI: 10.3389/fped.2022.1010600
Dynamic parameters for fluid responsiveness in mechanically ventilated children: A systematic review
Abstract
Objective: Fluid administration is the initial step of treatment of unstable pediatric patients. Evaluation of fluid responsiveness is crucial in mechanically ventilated children to avoid fluid overload, which increases mortality. We aim to review and compare the diagnostic performance of dynamically hemodynamic parameters for predicting fluid responsiveness in mechanically ventilated children.
Design: A systematic review was performed using four electronic databases, including PubMed, EMBASE, Scopus, and Central, for published articles from 1 January 2010 to 31 December 2020. Studies were included if they described diagnostic performance of dynamic parameters after fluid challenge was performed in mechanically ventilated children.
Settings: Pediatric intensive and cardiac intensive care unit, and operative room.
Patients: Children aged 1 month to 18 years old who were under mechanical ventilation and required an intravenous fluid challenge.
Measurements and main results: Twenty-seven studies were included in the systematic review, which included 1,005 participants and 1,138 fluid challenges. Respiratory variation in aortic peak velocity was reliable among dynamic parameters for predicting fluid responsiveness in mechanically ventilated children. All studies of respiratory variation in aortic peak velocity showed that the area under the receiver operating characteristic curve ranged from 0.71 to 1.00, and the cutoff value for determining fluid responsiveness ranged from 7% to 20%. Dynamic parameters based on arterial blood pressure (pulse pressure variation and stroke volume variation) were also used in children undergoing congenital heart surgery. The plethysmography variability index was used in children undergoing neurological and general surgery, including the pediatric intensive care patients.
Conclusions: The respiratory variation in aortic peak velocity exhibited a promising diagnostic performance across all populations in predicting fluid responsiveness in mechanically ventilated children. High sensitivity is advantageous in non-cardiac surgical patients and the pediatric intensive care unit because early fluid resuscitation improves survival in these patients. Furthermore, high specificity is beneficial in congenital heart surgery because fluid overload is particularly detrimental in this group of patients.
Systematic review registration: https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=206400.
Keywords: cardiac output; fluid therapy; hemodynamic; pediatric; predict.
© 2022 Yenjabog, Kanchongkittiphon, Chutipongtanate, Lertbunrian and Ungprasert.
Conflict of interest statement
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Figures
References
-
- Sutherland SM, Zappitelli M, Alexander SR, Chua AN, Brophy PD, Bunchman TE, et al. Fluid overload and mortality in children receiving continuous renal replacement therapy: the prospective pediatric continuous renal replacement therapy registry. Am J Kidney Dis. (2010) 55:316–25. 10.1053/j.ajkd.2009.10.048 - DOI - PubMed
Publication types
LinkOut - more resources
Full Text Sources