. 2023 Feb;31(2):249-257.
doi: 10.1016/j.joca.2022.10.017. Epub 2022 Nov 10.

Reproducibility of T and T2 quantification in a multi-vendor multi-site study

Affiliations

Reproducibility of T and T2 quantification in a multi-vendor multi-site study

R Lartey et al. Osteoarthritis Cartilage. 2023 Feb.

Abstract

Objective: To evaluate the multi-vendor multi-site reproducibility of two-dimensional (2D) multi-echo spin-echo (MESE) T2 mapping (product sequences); and to evaluate the longitudinal reproducibility of three-dimensional (3D) magnetization-prepared angle-modulated partitioned k-space spoiled gradient echo snapshots (MAPSS) T and T2 mapping (research sequences), and 2D MESE T2 mapping, separated by 6 months, in a multi-vendor multi-site setting.

Methods: Phantoms and volunteers (n = 5 from each site, n = 20 in total) were scanned on four 3 T magnetic resonance (MR) systems from four sites and three vendors (Siemens, General Electric, and Phillips). Two traveling volunteers (3 knees) scanned at all 4 sites at baseline and 6-month follow-up. Data was transferred to one site for centralized processing. Coefficients of variation (CVs) were calculated to evaluate reproducibility.

Results: For baseline 2D MESE T2 measures, average CV were 0.37-2.45% (intra-site) and 5.96% (inter-site) for phantoms, and 3.15-8.49% (intra-site) and 14.16% (inter-site) for volunteers. For longitudinal phantom data, intra-site CVs were 1.42-3.48% for 3D MAPSS T, 1.77-3.56% for 3D MAPSS T2, and 1.02-2.54% for 2D MESE T2. For the longitudinal volunteer data, the intra-site CVs were 2.60-4.86% for 3D MAPSS T, 3.33-7.25% for 3D MAPSS T2, and 3.11-8.77% for 2D MESE T2.

Conclusion: This study demonstrated excellent intra-site reproducibility of 2D MESE T2 imaging, while its inter-site variation was slightly higher than 3D MAPSS T2 imaging (10.06% as previously reported). This study also showed excellent reproducibility of longitudinal T and T2 cartilage quantification, in a multi-vendor multi-site setting for both product 2D MESE T2 and 3D MAPSS T1p/T2 research sequences.

Keywords: Cartilage imaging; Magnetic resonance imaging; Repeatability; Reproducibility; T(1ρ); T(2).

PubMed Disclaimer

References

    1. Li X, Majumdar S. Quantitative MRI of articular cartilage and its clinical applications. Journal of magnetic resonance imaging: JMRI. 2013; 38(5): 991–1008. 10.1002/jmri.24313 - DOI - PMC - PubMed
    1. Roemer FW, Demehri S, Omoumi P, Link TM, Kijowski R, Saarakkala S, et al. State of the Art: Imaging of Osteoarthritis-Revisited 2020. Radiology. 2020; 296(1): 5–21. 10.1148/radiol.2020192498 - DOI - PubMed
    1. Emanuel KS, Kellner LJ, Peters M, Haartmans M, Hooijmans MT, Emans PJ. The relation between the biochemical composition of knee articular cartilage and quantitative MRI: a systematic review and meta-analysis. Osteoarthritis and cartilage, 2022; 30(5): 650–662. 10.1016/j.joca.2021.10.016 - DOI - PubMed
    1. MacKay JW, Low S, Smith TO, Toms AP, McCaskie AW, Gilbert FJ. Systematic review and meta-analysis of the reliability and discriminative validity of cartilage compositional MRI in knee osteoarthritis. Osteoarthritis and cartilage. 2018; 26(9): 1140–1152. 10.1016/j.joca.2017.11.018 - DOI - PubMed
    1. Atkinson HF, Birmingham TB, Moyer RF, Yacoub D, Kanko LE, Bryant DM, et al. MRI T2 and T1ρ relaxation in patients at risk for knee osteoarthritis: a systematic review and meta-analysis. BMC musculoskeletal disorders. 2019; 20(1): 182. 10.1186/s12891-019-2547-7 - DOI - PMC - PubMed

Publication types