Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 May;81(5):558-565.
doi: 10.1016/j.annemergmed.2022.09.014. Epub 2022 Nov 10.

Comparison of YEARS and Adjust-Unlikely D-dimer Testing for Pulmonary Embolism in the Emergency Department

Affiliations

Comparison of YEARS and Adjust-Unlikely D-dimer Testing for Pulmonary Embolism in the Emergency Department

Kerstin de Wit et al. Ann Emerg Med. 2023 May.

Abstract

Study objective: We prospectively assessed the diagnostic accuracy of YEARS and a modified age-adjusted clinical decision rule ("Adjust-Unlikely") for pulmonary embolism (PE) testing in the emergency department.

Methods: This study was conducted in tertiary care Canadian emergency departments. When the D-dimer was <500 ng/ml, PE was excluded. Pulmonary imaging for PE was performed when the D-dimer was ≥500 ng/ml. Patients were followed for 30 days, and PE outcomes were independently adjudicated. Physicians systematically recorded the presence or absence of YEARS items (PE most likely, hemoptysis, signs of deep venous thrombosis) prior to D-dimer testing and imaging. We analyzed the diagnostic accuracy of YEARS and the "Adjust-Unlikely" rule. Age adjustment (age x 10 in those >50 years old) was applied in patients where PE was not the most likely diagnosis and 500 ng/ml threshold when PE was most likely.

Results: One thousand seven hundred three patients were included, median age 62 (50, 74), 58% female, PE prevalence 8.0%. YEARS sensitivity for PE diagnosis was 92.6% (87.0, 96.0%) and specificity 45.0% (42.5, 47.5%). Adjust-Unlikely sensitivity was 100.0% (97.2, 100.0%) and specificity 32.4% (30.1, 34.8%). Posttest probability of PE in the group of patients with PE excluded by D-dimer between 500 ng/ml and the adjusted limit was 2.8% (1.6, 5.1%) for YEARS and 0.0% (0.0, 2.6%) for the "Adjust-Unlikely" rule.

Conclusion: The "Adjust-Unlikely" rule would modestly reduce imaging and identify all cases of PE. YEARS would substantially reduce imaging but miss 1 in 14 cases of PE.

PubMed Disclaimer

Comment in

Publication types

Substances