High-fidelity fluid structure interaction simulations of turbulent-like aneurysm flows reveals high-frequency narrowband wall vibrations: A stimulus of mechanobiological relevance?
- PMID: 36375263
- DOI: 10.1016/j.jbiomech.2022.111369
High-fidelity fluid structure interaction simulations of turbulent-like aneurysm flows reveals high-frequency narrowband wall vibrations: A stimulus of mechanobiological relevance?
Abstract
Recent high-fidelity/resolution computational fluid dynamics simulations of intracranial aneurysm hemodynamics have revealed turbulent-like flows. We hypothesized that the associated high-frequency pressure fluctuations could promote aneurysm wall vibrations. We performed fully coupled high-fidelity transient fluid structure interaction simulations between the blood flow and compliant aneurysm sac wall taking 5,000 time steps per second using a 3D patient-specific model previously shown to harbour turbulent-like flow. Our results show that the flow velocity contained fluctuations with a smooth and continuously decaying energy up to ∼160Hz, and fluctuating pressures with characteristic frequency peaks at approximately 30, 130 and 210Hz. There was a strong two-way coupling between the pressure and the wall deformation, for which the frequency spectrum showed similar characteristics, but with a narrow band peak at ∼120Hz with large regional differences in amplitude up to 80μm. The physics of the flow is broadly consistent with clinical reports of turbulent-like flows, while the physics of the wall is consistent with reports of spectral peaks in aneurysm patients. As many aneurysms are known to harbour turbulent-like flows, wall vibrations could be a widespread phenomenon. Finally, since aneurysms are vascular pathologies by definition and many/most aneurysms do not have endothelial cells but still display a focal remodeling, we hypothesize that vibrations and stresses within the wall itself might play a role in the mechanobiological processes of vessel wall pathology.
Keywords: Aneurysm wall vibration; Cerebral aneurysm; Flow instabilities; Fluid structure interaction.
Copyright © 2022 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Conflict of interest statement
Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.