Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2022 Dec:177:121-133.
doi: 10.1016/j.radonc.2022.10.026. Epub 2022 Oct 28.

Diagnostic accuracy of MRI techniques for treatment response evaluation in patients with brain metastasis: A systematic review and meta-analysis

Affiliations
Free article
Meta-Analysis

Diagnostic accuracy of MRI techniques for treatment response evaluation in patients with brain metastasis: A systematic review and meta-analysis

Wouter H T Teunissen et al. Radiother Oncol. 2022 Dec.
Free article

Abstract

Background: Treatment response assessment in patients with brain metastasis uses contrast enhanced T1-weighted MRI. Advanced MRI techniques have been studied, but the diagnostic accuracy is not well known. Therefore, we performed a metaanalysis to assess the diagnostic accuracy of the currently available MRI techniques for treatment response.

Methods: A systematic literature search was done. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model. An independent cohort was used for DSC perfusion external validation of diagnostic accuracy.

Results: Anatomical MRI (16 studies, 726 lesions) showed a pooled sensitivity of 79% and a specificity of 76%. DCE perfusion (4 studies, 114 lesions) showed a pooled sensitivity of 74% and a specificity of 92%. DSC perfusion (12 studies, 418 lesions) showed a pooled sensitivity was 83% with a specificity of 78%. Diffusion weighted imaging (7 studies, 288 lesions) showed a pooled sensitivity of 67% and a specificity of 79%. MRS (4 studies, 54 lesions) showed a pooled sensitivity of 80% and a specificity of 78%. Combined techniques (6 studies, 375 lesions) showed a pooled sensitivity of 84% and a specificity of 88%. External validation of DSC showed a lower sensitivity and a higher specificity for the reported cut-off values included in this metaanalysis.

Conclusion: A combination of techniques shows the highest diagnostic accuracy differentiating tumor progression from treatment induced abnormalities. External validation of imaging results is important to better define the reliability of imaging results with the different techniques.

Keywords: Brain metastasis; MRI; Meta-analysis; Pseudoprogression; Treatment response.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Publication types

MeSH terms

LinkOut - more resources