Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Nov 25;9(1).
doi: 10.1088/2057-1976/aca336.

The use of dynamic CT imaging for tracking mandibular movements in a phantom

Affiliations

The use of dynamic CT imaging for tracking mandibular movements in a phantom

Stijn E F Huys et al. Biomed Phys Eng Express. .

Abstract

Purpose. The objective of this study was to analyse the possibilities of using 4D CT scanning for the tracking of patients' mandibles.Methods. A clinical 256-slice Revolution CT was used in obtaining 4D CT scans without table movement, with a novel mandibular phantom, mounted on a programmable six degrees-of-freedom Stewart Platform in motion. The phantom was used to simulate mandibular motions which are combinations of rotations with translations (depression, elevation, protrusion, retrusion and laterotrusion). The phantom was scanned five times during identical motion patterns with a dynamic CT acquisition protocol. An image processing workflow consisting of a pairwise rigid registration and semi-automatic segmentation was developed to extract kinematic parameters (cardan angles and point-of-interest displacements) from the dynamic sequences. Reproducibility was investigated by the 95% confidence interval and the absorbed organ dose to organs of interest in the primary beam were also estimated and compared to those of a standard CT scan of the brainResults. The maximum average 95% confidence interval for the displacement across all time points for the five repetitions was 0.61 mm (Yaxis). In terms of rotations, the maximum average 95% confidence interval across all time points for the five repetitions was 1.39° (Xaxis). The effective dose for the dynamic scan was found to be 1.3 mSv, for a CTDIvolof 63.95 mGy and a DLP of 1023.14 mGycm. The absorbed organ doses were similar to organ doses during a clinical head CT scan.Conclusions. A framework is proposed to use 4D CT scanning as a possible methodology to evaluate the motion of the temporomandibular joint. The scanning protocol allows to visualise the motion by applying a semi-automated segmentation and registration. A graphical representation of all displacements in the three spatial dimensions can depict multiple points-of-interest at once during the same acquisition. A novel type of phantom was also introduced which simulates mandibular movement with six degrees-of-freedom (three translations and three rotations).

Keywords: four-dimensional computed tomography; imaging; mandible; phantoms; radiometry; temporomandibular joint.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources