Carotid flow as a surrogate of the left ventricular stroke volume
- PMID: 36399216
- DOI: 10.1007/s10877-022-00938-7
Carotid flow as a surrogate of the left ventricular stroke volume
Abstract
Transthoracic echocardiography (TTE) is a fundamental tool for hemodynamic monitoring in critical patients. It allows evaluating the left ventricle's stroke volume based on the measurement of the velocity-time integral (VTI) of the left ventricle outflow tract (LVOT). However, in the intensive care unit obtaining adequate echocardiographic views may present a challenge. We propose to measure, as a surrogate of the stroke volume, the carotid flow with a novel technique. This is an observational, prospective, and simple blind study, conducted in the intensive care unit of Sanatorio de los Arcos and Hospital Aleman, in Buenos Aires, Argentina. We measured the carotid systodiastolic flow (CSD) VTI and the carotid systolic flow (CS) VTI at the level of the left supraclavicular fossa and we compared it with the LVOT VTI obtained by TTE. We evaluated 43 subjects. Spearman's correlation coefficient between LVOT VTI and CS VTI was 0.81 (95% CI 0.67-0.89) and between LVOT VTI and CSD VTI was 0.89 (95% CI 0.81-0.94). The Bland-Altman method analysis of the 5-chamber apical window LVOT VTI compared to the CSD VTI showed a bias of - 0.2 (95% CI - 0.82 to 0.43), with a concordance interval between - 4.2 (95% CI - 5.2 to - 3.1) and 3.8 cm (95% CI 2.7 to 4.9). The percentage error was 37.9%. Almost 100% of the values fell within the concordance limits, and no trend was observed in bias across the spectrum of mean variables. Although the CSD VTI could not be interchangeable with the LVOT VTI, it could be considered as its surrogate.
Keywords: Cardiac output; Carotid flow; Hemodynamic monitoring; POCUS; Stroke volume.
© 2022. The Author(s), under exclusive licence to Springer Nature B.V.
Comment in
-
A theoretical foundation for relating the velocity time integrals of the left ventricular outflow tract and common carotid artery.J Clin Monit Comput. 2023 Jun;37(3):937-939. doi: 10.1007/s10877-022-00969-0. Epub 2023 Jan 10. J Clin Monit Comput. 2023. PMID: 36625983 Free PMC article. No abstract available.
References
-
- Blanco P. Rationale for using the velocity-time integral and the minute distance for assessing the stroke volume and cardiac output in point-of-care settings. Ultrasound J. 2020;12(1):21. https://doi.org/10.1186/s13089-020-00170-x . - DOI - PubMed - PMC
-
- Mercado P, Maizel J, Beyls C, Titeca-Beauport D, Joris M, Kontar L, Riviere A, Bonef O, Soupison T, Tribouilloy C, de Cagny B, Slama M. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient. Crit Care. 2017;21(1):136. https://doi.org/10.1186/s13054-017-1737-7 . - DOI - PubMed - PMC
-
- Wang J, Zhou D, Gao Y, Wu Z, Wang X, Lv C. Effect of VTILVOT variation rate on the assessment of fluid responsiveness in septic shock patients. Med (Baltim). 2020;20(47):e22702. https://doi.org/10.1097/MD.000000000022702 . - DOI
-
- Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL. Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest. 2001;119(3):867–73. https://doi.org/10.1378/chest.119.3.867 . - DOI - PubMed
-
- Biais M, Vidil L, Sarrabay P, Cottenceau V, Revel P, Sztark F. Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo/FloTrac device. Crit Care. 2009;13(6):R195. https://doi.org/10.1186/cc8195 . - DOI - PubMed - PMC
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources