Analysis of the incidence and influencing factors associated with binary restenosis of target lesions after drug-coated balloon angioplasty for patients with in-stent restenosis
- PMID: 36404303
- PMCID: PMC9677633
- DOI: 10.1186/s12872-022-02923-z
Analysis of the incidence and influencing factors associated with binary restenosis of target lesions after drug-coated balloon angioplasty for patients with in-stent restenosis
Abstract
Background: Drug-coated balloon (DCB) is a novel and effective device for coronary artery disease patients with in-stent restenosis (ISR). However, the incidence and possible influencing factors associated with binary restenosis have not yet been adequately assessed.
Methods: The data are extracted from a prospective, multicenter, randomized controlled trial. A total of 211 patients with ISR were enrolled at 13 centers from August 2017 to October 2018 and treated with DCB. At the 9-month coronary angiographic follow-up, patients were divided into restenosis and non-restenosis groups, and demographic data, lesion features, and laboratory tests were retrospectively reviewed. Furthermore, logistic regression analysis was used to identify possible influencing factors.
Results: All patients successfully underwent treatment, and 166 patients with 190 lesions took part in angiography follow-ups at 9 months. Of these, 41 patients with 44 target lesions developed restenosis following treatment, and the incidence of ISR was 24.7%. There were significant differences in the average length of target lesions and the number of multivessel lesions and fasting plasma glucose (FBG) between the two groups (p < 0.05). Demographic data, cardiac risk factors, left ventricular ejection fractions (LVEF), blood routine tests, biochemical tests, and other features of devices and lesions showed no difference. Logistic regression analyses showed that FBG > 6.1 mmol/L (OR: 7.185 95% CI: 2.939-17.567 P < 0.001) and length of lesion (OR:1.046 95% CI: 1.001-1.093 P = 0.046) were associated risk factors.
Conclusions: The longer length of lesions, more target lesions and FBG > 6.1 mmol/L per individual may be characteristics of patients showing ISR following treatment. Studies with larger sample size, and more complete follow-up data are needed in the future to expend on these findings.
Trial registration: No.: NCT04213378, first posted date (30/12/2019).
Keywords: Coronary artery disease; Drug-coated balloon; In-stent restenosis; Influencing factors.
© 2022. The Author(s).
Conflict of interest statement
The authors declare that they have no competing interests.
Similar articles
-
Drug-coated balloon angioplasty: predicting outcomes based on different patterns of drug-eluting stent restenosis.Int J Cardiovasc Imaging. 2020 Feb;36(2):171-178. doi: 10.1007/s10554-019-01681-y. Epub 2020 Jan 9. Int J Cardiovasc Imaging. 2020. PMID: 31919705
-
Angiography and Optical Coherence Tomography Assessment of the Drug-Coated Balloon ESSENTIAL for the Treatment of In-Stent Restenosis.Cardiovasc Revasc Med. 2020 Apr;21(4):508-513. doi: 10.1016/j.carrev.2019.07.021. Epub 2019 Jul 23. Cardiovasc Revasc Med. 2020. PMID: 31401071
-
Neointimal Modification With Scoring Balloon and Efficacy of Drug-Coated Balloon Therapy in Patients With Restenosis in Drug-Eluting Coronary Stents: A Randomized Controlled Trial.JACC Cardiovasc Interv. 2017 Jul 10;10(13):1332-1340. doi: 10.1016/j.jcin.2017.04.024. JACC Cardiovasc Interv. 2017. PMID: 28683939 Clinical Trial.
-
Incidence and predictors of reCurrent restenosis after drug-coated balloon Angioplasty for Restenosis of a drUg-eluting Stent: The ICARUS Cooperation.Rev Esp Cardiol (Engl Ed). 2018 Aug;71(8):620-627. doi: 10.1016/j.rec.2017.08.005. Epub 2017 Sep 13. Rev Esp Cardiol (Engl Ed). 2018. PMID: 28916429 Review. English, Spanish.
-
Long-term clinical safety and efficacy of drug-coated balloon in the treatment of in-stent restenosis: A meta-analysis and systematic review.Catheter Cardiovasc Interv. 2020 Aug;96(2):E129-E141. doi: 10.1002/ccd.28572. Epub 2019 Nov 12. Catheter Cardiovasc Interv. 2020. PMID: 31714010
Cited by
-
Factors influencing coronary artery target lesion revascularization after drug-coated balloon angioplasty.Front Cardiovasc Med. 2024 May 16;11:1387074. doi: 10.3389/fcvm.2024.1387074. eCollection 2024. Front Cardiovasc Med. 2024. PMID: 38818212 Free PMC article.
References
-
- Waksman R, Steinvil A. In-stent restenosis? The raiders of the magic remedy. Circ Cardiovasc Interv. 2016;9(7). - PubMed
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Medical