Reliability of latex agglutination tests for identification of Staphylococcus aureus resistant to oxacillin
- PMID: 3640773
- PMCID: PMC269109
- DOI: 10.1128/jcm.24.6.1104-1106.1986
Reliability of latex agglutination tests for identification of Staphylococcus aureus resistant to oxacillin
Abstract
Commercial latex agglutination tests (LATs) for the simultaneous detection of clumping factor and protein A are gaining increased acceptance as a means of identifying Staphylococcus aureus. We evaluated two LATs (Accu-Staph; Carr-Scarborough, Decatur, Ga.; Staphaurex; Wellcome, Dartford, England) with particular emphasis on their ability to correctly identify oxacillin-resistant S. aureus. We tested 59 oxacillin-resistant S. aureus, 136 oxacillin-susceptible S. aureus, and 92 coagulase-negative staphylococcal strains with the two LATs and with thermonuclease, slide clumping factor, tube coagulase, and protein A hemagglutination tests. Clumping factor and protein A were present in 96.9 and 82.1% of our S. aureus strains, respectively. Accu-Staph correctly identified 92.8% and Staphaurex correctly identified 91.3% of S. aureus strains. No significant difference in LAT positivity rates, presence of clumping factor, or presence of protein A was found between oxacillin-resistant and -susceptible S. aureus. Overall, there were 31 false-negative LATs for 20 S. aureus strains, 14 with Accu-Staph and 17 with Staphaurex. Ninety-five percent of these strains possessed either clumping factor or protein A or both when these factors were determined independently. There were five false-positive LATs for four strains of coagulase-negative staphylococci (three Staphylococcus epidermidis and one Staphylococcus warneri), four with Accu-Staph and one with Staphaurex. Clumping factor was present in one S. warneri strain. Thus, the specificities of Accu-Staph, Staphaurex, and the clumping factor test were 95.6, 98.9, and 98.9%, respectively. Our results indicated that LATs identify oxacillin-resistant and -susceptible S. aureus equally well; however, they offer no greater sensitivity or specificity than the clumping factor test for identification of S. aureus.
Similar articles
-
Performance of four slide agglutination methods for identification of Staphylococcus aureus when testing methicillin-resistant staphylococci.J Clin Microbiol. 1987 Jan;25(1):181-2. doi: 10.1128/jcm.25.1.181-182.1987. J Clin Microbiol. 1987. PMID: 3641849 Free PMC article.
-
New latex reagent using monoclonal antibodies to capsular polysaccharide for reliable identification of both oxacillin-susceptible and oxacillin-resistant Staphylococcus aureus.J Clin Microbiol. 1993 May;31(5):1342-4. doi: 10.1128/jcm.31.5.1342-1344.1993. J Clin Microbiol. 1993. PMID: 8501240 Free PMC article.
-
Coagulase production by strains of Staphylococcus aureus of differing resistance characters: a comparison of two traditional methods with a latex agglutination system detecting both clumping factor and protein A.J Clin Pathol. 1986 Apr;39(4):371-5. doi: 10.1136/jcp.39.4.371. J Clin Pathol. 1986. PMID: 3634779 Free PMC article.
-
Evaluation of rapid coagulase methods for the identification of Staphylococcus aureus.J Clin Microbiol. 1986 May;23(5):916-9. doi: 10.1128/jcm.23.5.916-919.1986. J Clin Microbiol. 1986. PMID: 3635533 Free PMC article.
-
Current Limitations of Staph Infection Diagnostics, and the Role for VOCs in Achieving Culture-Independent Detection.Pathogens. 2023 Jan 24;12(2):181. doi: 10.3390/pathogens12020181. Pathogens. 2023. PMID: 36839453 Free PMC article. Review.
Cited by
-
Evaluation of a direct identification method for Staphylococcus aureus from blood culture broth.J Clin Microbiol. 1988 Jul;26(7):1404-5. doi: 10.1128/jcm.26.7.1404-1405.1988. J Clin Microbiol. 1988. PMID: 3410952 Free PMC article.
-
Staphylococcus aureus strains which are not identified by rapid agglutination methods are of capsular serotype 5.J Clin Microbiol. 1989 Jun;27(6):1372-4. doi: 10.1128/jcm.27.6.1372-1374.1989. J Clin Microbiol. 1989. PMID: 2754004 Free PMC article.
-
Use of commercial particle agglutination systems for the rapid identification of methicillin-susceptible and methicillin-resistant Staphylococcus aureus.Eur J Clin Microbiol Infect Dis. 1994 Jan;13(1):86-9. doi: 10.1007/BF02026132. Eur J Clin Microbiol Infect Dis. 1994. PMID: 8168569
-
Evaluation of new agglutination test for identification of oxacillin-susceptible and oxacillin-resistant Staphylococcus aureus.J Clin Microbiol. 1995 May;33(5):1333-4. doi: 10.1128/jcm.33.5.1333-1334.1995. J Clin Microbiol. 1995. PMID: 7615750 Free PMC article.
-
Coagulase testing compared with commercial kits for routinely identifying Staphylococcus aureus.J Clin Pathol. 1990 Mar;43(3):246-52. doi: 10.1136/jcp.43.3.246. J Clin Pathol. 1990. PMID: 2185284 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials