Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jun;38(6):883-887.
doi: 10.1111/jgh.16073. Epub 2023 Jan 23.

Application of artificial intelligence to digital-rapid on-site cytopathology evaluation during endoscopic ultrasound-guided fine needle aspiration: A proof-of-concept study

Affiliations

Application of artificial intelligence to digital-rapid on-site cytopathology evaluation during endoscopic ultrasound-guided fine needle aspiration: A proof-of-concept study

Rong Lin et al. J Gastroenterol Hepatol. 2023 Jun.

Abstract

Background: During endoscopic ultrasound-guided fine needle aspiration (EUS-FNA), cytopathology with rapid on-site evaluation (ROSE) can improve diagnostic yield and accuracy. However, ROSE is unavailable in most Asian and European institutions because of the shortage of cytopathologists. Therefore, developing computer-assisted diagnostic tools to replace manual ROSE is crucial. Herein, we reported the validation of an artificial intelligence (AI)-based model (ROSE-AI model) to substitute manual ROSE during EUS-FNA.

Methods: A total of 467 digitized images from Diff-Quik (D&F)-stained EUS-FNA slides were divided into training (3642 tiles from 367 images) and internal validation (916 tiles from 100 images) datasets. The ROSE-AI model was trained and validated using training and internal validation datasets, respectively. The specificity was emphasized while developing the model. Then, we evaluated the AI model on a 693-image external dataset. We assessed the performance of the AI model to detect cancer cells (CCs) regarding the accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV).

Results: The ROSE-AI model achieved an accuracy of 83.4% in the internal validation dataset and 88.7% in the external test dataset. The sensitivity and PPV were 79.1% and 71.7% in internal validation dataset and 78.0% and 60.7% in external test dataset, respectively.

Conclusion: We provided a proof of concept that AI can be used to replace manual ROSE during EUS-FNA. The ROSE-AI model can address the shortage of cytopathologists and make ROSE available in more institutes.

Keywords: AI; EUS-FNA; ROSE; accuracy; cytopathologists.

PubMed Disclaimer

Comment in

References

    1. Tanaka K, Hayashi T, Utsunomiya R et al. Endoscopic ultrasound-guided fine needle aspiration for diagnosing pancreatic mass in patients with surgically altered upper gastrointestinal anatomy. Dig. Endosc. 2020; 32: 967-973.
    1. Yoshinaga S, Itoi T, Yamao K et al. Safety and efficacy of endoscopic ultrasound-guided fine needle aspiration for pancreatic masses: a prospective multicenter study. Dig. Endosc. 2020; 32: 114-126.
    1. Dumonceau JM, Deprez PH, Jenssen C et al. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) clinical guideline - updated January 2017. Endoscopy 2017; 49: 695-714.
    1. Chang KJ, Nguyen P, Erickson RA, Durbin TE, Katz KD. The clinical utility of endoscopic ultrasound-guided fine-needle aspiration in the diagnosis and staging of pancreatic carcinoma. Gastrointest. Endosc. 1997; 45: 387-393.
    1. Schmidt RL, Walker BS, Howard K, Layfield LJ, Adler DG. Rapid on-site evaluation reduces needle passes in endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesions: a risk-benefit analysis. Dig. Dis. Sci. 2013; 58: 3280-3286.

MeSH terms

LinkOut - more resources