Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Mar;31(1):1-8.
doi: 10.1080/09273972.2022.2141272. Epub 2022 Nov 22.

Binocular contrast sensitivity in patients with intermittent exotropia in relation to angle of strabismus and level of compensation

Affiliations

Binocular contrast sensitivity in patients with intermittent exotropia in relation to angle of strabismus and level of compensation

Fatemeh Moradi et al. Strabismus. 2023 Mar.

Abstract

Intermittent exotropia (IXT) causes photophobia, and photophobia has been studied by measurement of contrast sensitivity (CS). CS was reduced in children with IXT. We compared binocular CS (BCS) in patients with IXT and normal subjects in relation to the angle of strabismus and control of IXT. This case-control study was performed on 40 patients with IXT and 40 normal subjects who were examined with the CSV1000 CS device in mesopic (3 cd/m2) and photopic (85 cd/m2) conditions with and without a glare stimulus at 3, 6, 12, and 18 cycle/degree (cpd) spatial frequencies. The angle of strabismus and near stereoacuity were also measured. The patient's IXT compensation was graded based on the office control scale. The mean age for IXT and normal participants were 12.30 ± 0.60 (range, 6-18) and 11.00 ± 0.78 (range, 6-18) years, respectively (P = .34). The IXT patients had lower binocular CS than controls at all spatial frequencies (P < .001). The largest decrease in CS occurred at 6 cpd spatial frequency under mesopic condition (1.61 ± 0.07 vs 1.38 ± 0.15, P < .001) and photopic condition with glare (2.03 ± 0.06 vs 1.77 ± 0.13, P < .001). Patients with better control scores had higher levels of BCS; also, the score of BCS showed a significant decrease in patients with a deviation of 25 prism diopter or more, compared to those with less deviation. BCS correlated at 3 and 6 cpd with near stereoacuity (r = -0.652, P < .001 and r = -0.613, P < .001). Binocular CS in patients with IXT correlates with the angle of strabismus and level of compensation.

Keywords: Contrast sensitivity; glare; intermittent exotropia; stereopsis.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources