Accuracy of ultrasound for the detection of placenta accreta spectrum in a universal screening population

Affiliations

Accuracy of ultrasound for the detection of placenta accreta spectrum in a universal screening population

Hanna Elise Baumann et al. Int J Gynaecol Obstet. 2023 Jun.

Abstract

Objectives: The current study aimed to determine the sensitivity and specificity of ultrasound for the diagnosis of placenta accreta spectrum (PAS) in a universal screening population and assesses the added value of magnetic resonance imaging (MRI).

Methods: This retrospective analysis evaluated 5219 patients with singleton pregnancies who had a standardized ultrasound (US) examination in our unit and delivered at our institution between 2014 and 2019.

Results: A total of 181 (3.5%) of 5219 (100%) patients had a suspicion or diagnosis of PAS with US. The accuracy of US in detecting placenta increta/percreta showed a sensitivity of 100%, specificity of 99.9%, positive predictive value of 82.4%, and a negative predictive value of 100%. The diagnosis of all forms of PAS showed a sensitivity of 25.8%, specificity of 99.8%, positive predictive value of 80.8%, and a negative predictive value of 97.7%. MRI was concordant with US in 11 of 14 (78.5%) cases of severe forms of PAS and in three of 15 (20.0%) cases with placenta accreta.

Conclusion: A standardized US evaluation can be applied in a universal screening setting for the diagnosis of severe forms of PAS. MRI is a complementary examination in severe forms of PAS but seems of limited value to discriminate placenta accreta from placenta increta/percreta.

Keywords: magnetic resonance imaging; placenta accreta; placenta increta; placenta percreta; prenatal diagnosis; ultrasound.

PubMed Disclaimer

References

REFERENCES

    1. Perotto L, Zimmermann R, Quack Loetscher KC. Maternal mortality in Switzerland 2005-2014. Swiss Med Wkly. 2020;150:w20345.
    1. Silver RM, Branch DW. Placenta accreta spectrum. N Engl J Med. 2018;378(16):1529-1536.
    1. Jauniaux E, Ayres-de-Campos D, Langhoff-Roos J, Fox KA, Collins S, FIGO placenta Accreta diagnosis and management expert consensus panel. FIGO classification for the clinical diagnosis of placenta accreta spectrum disorders. Int J Gynecol Obstet. 2019;146(1):20-24.
    1. Hobson SR, Kingdom JC, Murji A, et al. No. 383-screening, diagnosis, and management of placenta accreta spectrum disorders. J Obstet Gynaecol Can. 2019;41(7):1035-1049.
    1. Lee W, Fox KA, Cassady CI, et al. Placenta accreta spectrum 2021: roundtable discussion. J Ultrasound Med. 2022;41:7-15.

LinkOut - more resources