Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jan 4:1687:463694.
doi: 10.1016/j.chroma.2022.463694. Epub 2022 Dec 1.

Determination of oxidized 1-palmitoyl-2-arachidonoyl-sn-glycero-3-phosphocholine products in human very low-density lipoproteins by nonaqueous low-flow capillary electrophoresis-mass spectrometry

Affiliations

Determination of oxidized 1-palmitoyl-2-arachidonoyl-sn-glycero-3-phosphocholine products in human very low-density lipoproteins by nonaqueous low-flow capillary electrophoresis-mass spectrometry

Chiz-Tzung Chang et al. J Chromatogr A. .

Abstract

A simple and fast low-flow capillary electrophoresis-mass spectrometry (low-flow CE-MS) method has been developed to analyze oxidized 1-palmitoyl-2-arachidonoyl-sn-glycero-3-phosphocholine (ox-PAPC) products in human very low-density lipoproteins (VLDLs). Native PAPC standard was analyzed to optimize the low-flow CE-MS method. The optimal CE conditions included separation buffer (60% (v/v) acetonitrile, 40% (v/v) methanol, 0.1% (v/v) water, 0.5% (v/v) formic acid, 20 mM ammonium acetate), sheath liquid (60% (v/v) acetonitrile, 40% (v/v) methanol, 0.1% (v/v) water, 20 mM ammonium acetate), separation voltage (20 kV), separation capillary internal diameter (i.d.) (75 µm), separation capillary temperature (23˚C) and sample injection time (6 s). The selected MS conditions included heated capillary temperature (250°C), capillary voltage (10 V), and injection time (1 s). Sheath gas was not used in this study. The total ion chromatograms (TICs), extracted ion chromatograms (EICs) and MS spectra of native PAPC standard and its in vitro oxidation products showed good repeatability and sensitivity. To determine the ox-PAPC products in human VLDLs, the EICs and MS spectra of VLDLs were compared with the in vitro oxidation products of native PAPC standard. For native PAPC standard, the measured linear range was 2.5 - 100.0 µg/mL, and the coefficients of determination (R2) was 0.9994. The concentration limit of detection (LOD) was 0.44 µg/mL, and the concentration limit of quantitation (LOQ) was 1.34 µg/mL. A total of 21 ox-PAPC products were analyzed for the VLDLs of healthy and uremic subjects. The levels of 7 short-chain and 5 long-chain ox-PAPC products on uremic VLDLs were significantly higher than healthy VLDLs. This simple low-flow CE-MS method might be a good alternative for LC-MS for the analysis of ox-PAPC products. Furthermore, it might also help scientists to expedite the search for uremic biomarkers.

Keywords: Low-flow CE-MS; Oxidized 1-palmitoyl-2-arachidonoyl-sn-glycero-3-phosphocholine; Uremia; Very low-density lipoprotein.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

LinkOut - more resources