3D-QCNet - A pipeline for automated artifact detection in diffusion MRI images
- PMID: 36502764
- PMCID: PMC10494975
- DOI: 10.1016/j.compmedimag.2022.102151
3D-QCNet - A pipeline for automated artifact detection in diffusion MRI images
Abstract
Artifacts are a common occurrence in Diffusion MRI (dMRI) scans. Identifying and removing them is essential to ensure the accuracy and viability of any post-processing carried out on these scans. This makes quality control (QC) a crucial first step prior to any analysis of dMRI data. Several QC methods for artifact detection exist, however they suffer from problems like requiring manual intervention and the inability to generalize across different artifacts and datasets. In this paper, we propose an automated deep learning (DL) pipeline that utilizes a 3D-Densenet architecture to train a model on diffusion volumes for automatic artifact detection. Our method is validated on 9000 volumes sourced from 7 large clinical datasets spanning different acquisition protocols (with different gradient directions, high and low b-values, single-shell and multi-shell acquisitions) from multiple scanners. Additionally, they represent diverse subject demographics including age, sex and the presence or absence of pathologies. Our QC method is found to accurately generalize across this heterogenous data by correctly detecting 92% artifacts on average across our test set. This consistent performance over diverse datasets underlines the generalizability of our method, which currently is a significant barrier hindering the widespread adoption of automated QC techniques. Thus, 3D-QCNet can be integrated into diffusion pipelines to effectively automate the arduous and time-intensive process of artifact detection.
Keywords: Artifacts; Deep learning; Diffusion MRI; MRI; Quality control.
Copyright © 2022. Published by Elsevier Ltd.
Conflict of interest statement
Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Figures
References
-
- Andersson JL, Graham MS, Zsoldos E, Sotiropoulos SN, 2016. Incorporating outlier detection and replacement into a non-parametric framework for movement and distortion correction of diffusion MR images. Neuroimage 141, 556–572. - PubMed
-
- Bammer R, Markl M, Barnett A, Acar B, Alley M, Pelc N, Glover G, Moseley M, 2003. Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion-weighted imaging. Magn. Reson. Med.: Off. J. Int. Soc. Magn. Reson. Med 50 (3), 560–569. - PubMed
Publication types
MeSH terms
Grants and funding
- R01 NS065980/NS/NINDS NIH HHS/United States
- UL1 TR000003/TR/NCATS NIH HHS/United States
- RF1 AG054409/AG/NIA NIH HHS/United States
- S10 OD023495/OD/NIH HHS/United States
- R01 MH117807/MH/NIMH NIH HHS/United States
- U01 NS086090/NS/NINDS NIH HHS/United States
- R01 AG055606/AG/NIA NIH HHS/United States
- UL1 RR024134/RR/NCRR NIH HHS/United States
- HHSN268200900048C/HL/NHLBI NIH HHS/United States
- R01 DC008871/DC/NIDCD NIH HHS/United States
- HHSN268200900040C/HL/NHLBI NIH HHS/United States
- HHSN268200900046C/HL/NHLBI NIH HHS/United States
- HHSN268200900049C/HL/NHLBI NIH HHS/United States
- HHSN268200900047C/HL/NHLBI NIH HHS/United States
LinkOut - more resources
Full Text Sources