Defective determination of synthetic cathinones in blood for forensic investigation
Abstract
Antemortem specimens are sometimes the sole sources available for forensic investigation, and samples collected in nonideal ways are inevitably employed to achieve toxicological analysis. It is essential to assess the effects of blood collection tubes on the recoveries of emerging synthetic cathinones (SC) to estimate actual drug concentrations, and no such systematic investigations have been previously carried out. Seventy-one SC with various LogP values were employed to examine commonly used blood collection tubes, including plasma tubes, serum tubes and gel-containing tubes in recoveries which determined by a reliable LC-MS/MS method. Significantly poor recoveries for hydrophobic SC were obtained using serum separating tubes (SST). Notably, the suppressed recoveries in SST can be reversed by adding anticoagulants. Adding a procoagulant to a plasma separating tube (PST) considerably reduced recoveries, which indicated that clotting processes in the presence of polymeric gels contributed to poor recoveries of these hydrophobic drugs. In this study, we find that clotting formation in the presence of polymeric gels could significantly affect the determination of hydrophobic drugs. However, in real-world scenarios, nonideal collection methods are inevitably employed for antemortem specimens. Thus, it is important to rigorously interpret forensic toxicological results, especially for susceptible species.
Keywords: Blood collection tubes; Forensic toxicology; LC-MS/MS; Synthetic cathinones.
Copyright © 2022 Elsevier B.V. All rights reserved.
Conflict of interest statement
Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Similar articles
-
The right blood collection tube for therapeutic drug monitoring and toxicology screening procedures: Standard tubes, gel or mechanical separator?Clin Chim Acta. 2019 Jan;488:196-201. doi: 10.1016/j.cca.2018.10.043. Epub 2018 Nov 12. Clin Chim Acta. 2019. PMID: 30439354
-
Influence of long-term storage temperatures and sodium fluoride preservation on the stability of synthetic cathinones and dihydro-metabolites in human whole blood.Forensic Toxicol. 2023 Jan;41(1):81-93. doi: 10.1007/s11419-022-00634-w. Epub 2022 Aug 6. Forensic Toxicol. 2023. PMID: 36652059 Free PMC article.
-
Stability of Direct Oral Anticoagulants and Antiarrhythmic Drugs in Serum Collected in Standard (Nongel) Serum Tubes Versus Tubes Containing Gel Separators.Ther Drug Monit. 2022 Apr 1;44(2):328-334. doi: 10.1097/FTD.0000000000000915. Ther Drug Monit. 2022. PMID: 34310545
-
Development and validation of a chiral LC-MS/MS method for the separation and quantification of four synthetic cathinones in human whole blood and its application in stability analysis.Talanta. 2023 Feb 1;253:123986. doi: 10.1016/j.talanta.2022.123986. Epub 2022 Oct 4. Talanta. 2023. PMID: 36228559
-
Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology.Clin Biochem. 2011 Jan;44(1):54-65. doi: 10.1016/j.clinbiochem.2010.08.008. Epub 2010 Aug 13. Clin Biochem. 2011. PMID: 20709050 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources