. 2023 Jan 1;37(1):35-40.
doi: 10.1519/JSC.0000000000004207. Epub 2022 Jan 5.

Validity and Test-Retest Reliability of the Vmaxpro Sensor for Evaluation of Movement Velocity in the Deep Squat

Affiliations

Validity and Test-Retest Reliability of the Vmaxpro Sensor for Evaluation of Movement Velocity in the Deep Squat

Joshua F Feuerbacher et al. J Strength Cond Res. .

Abstract

Feuerbacher, JF, Jacobs, MW, Dragutinovic, B, Goldmann, J-P, Cheng, S, and Schumann, M. Validity and test-retest reliability of the Vmaxpro sensor for evaluation of movement velocity in the deep squat. J Strength Cond Res 37(1): 35-40, 2023-We aimed at assessing the validity and test-retest reliability of the inertial measurement unit-based Vmaxpro sensor compared with a Vicon 3D motion capture system and the T-Force sensor during an incremental 1-repetition maximum (1RM) test and at submaximal loads. Nineteen subjects reported to the laboratory for the 1RM test sessions, whereas 15 subjects carried out another 3 sessions consisting of 3 repetitions with 4 different intensities (30, 50, 70, and 90% of 1RM) to determine the intra- and interday reliability. The Vmaxpro sensor showed high validity (Vicon: R2 = 0.935; T-Force: R2 = 0.968) but an overestimation of the mean velocities (MVs) of 0.06 ± 0.08 m·s-1 and 0.06 ± 0.06 m·s-1 compared with Vicon and T-Force, respectively. Regression analysis indicated a systematic bias that is increasing with higher MVs. The intraclass correlation coefficients (ICCs) for Vmaxpro were moderate to high for intraday (ICC: 0.662-0.938; p ≤ 0.05) and for interday (ICC: 0.568-0.837; p ≤ 0.05) reliability, respectively. The Vmaxpro is a valid and reliable measurement device that can be used to monitor movement velocities within a training session. However, practitioners should be cautious when assessing movement velocities on separate days because of the moderate interday reliability.

PubMed Disclaimer

References

    1. Ahmad N, Ghazilla RAR, Khairi NM, Kasi V. Reviews on various inertial measurement unit (IMU) sensor applications. Int J Signal Process Syst 1: 256–262, 2013.
    1. Aroganam G, Manivannan N, Harrison D. Review on wearable technology sensors used in consumer sport applications. Sensors (Basel) 19: 1983, 2019.
    1. Balsalobre-Fernández C, Cordón Á, Unquiles N, Muñoz-García D. Movement velocity in the chair squat is associated with measures of functional capacity and cognition in elderly people at low risk of fall. PeerJ 6: e4712, 2018.
    1. Balsalobre-Fernández C, Kuzdub M, Poveda-Ortiz P, Campo-Vecino JD. Validity and reliability of the PUSH wearable device to measure movement velocity during the back squat exercise. J Strength Cond Res 30: 1968–1974, 2016.
    1. Clemente FM, Akyildiz Z, Pino-Ortega J, Rico-González M. Validity and reliability of the inertial measurement unit for barbell velocity assessments: A systematic review. Sensors 21: 2511, 2021.

LinkOut - more resources