Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Mar 1:254:124188.
doi: 10.1016/j.talanta.2022.124188. Epub 2022 Dec 8.

Poly-(MMA-IL) filter paper: A new class of paper-based analytical device for thin-film microextraction of multi-class antibiotics in environmental water samples using LC-MS/MS analysis

Affiliations

Poly-(MMA-IL) filter paper: A new class of paper-based analytical device for thin-film microextraction of multi-class antibiotics in environmental water samples using LC-MS/MS analysis

Mohamad Shariff Shahriman et al. Talanta. .

Abstract

A paper-based polymeric ionic liquid (p-Poly-(MMA-IL)) was successfully developed by grafting the polymeric ionic liquid on the surface of commercial filter paper (FP) by using the dipping method, presenting a new cost-effective film. The newly developed p-Poly-(MMA-IL) FP was then applied as a paper-based thin-film microextraction (p-TFME) analytical device to extract 14 compounds as representative of five groups of antibiotic drugs, which were sulfonamides, tetracyclines, fluoroquinolones, penicillin and macrolides in environmental water samples. Besides, p-Poly-(MMA-IL) FP, p-Poly-(MMA) FP, and unmodified filter paper were successfully characterised by FTIR, NMR, FESEM, TGA, and XRD techniques. They underwent significant parameters optimisation, which affected the extraction efficiency. Under optimal conditions, the proposed (p-Poly-(MMA-IL) FP-TFME) device method was evaluated and applied to analyse multi-class antibiotic drugs in environmental water samples by using a liquid chromatography-mass spectrometry (LC-MS). The validation method showed that a good linearity (0.1 μg L-1 - 500 μg L-1) was noted (R2 > 0.993, n = 3). Detection and quantification limits were within 0.05 μg L-1 - 4.52 μg L-1 and 0.15 μg L-1 - 13.6 μg L-1, respectively. The relative standard deviation (RSD) values ranged at 1.4%-12.2% (intra-day, n = 15) and 4.4%-11.0% (inter-day, n = 10). The extraction recoveries of environmental water samples ranged from 79.1% to 126.8%, with an RSD of less than 15.4% (n = 3). The newly developed paper-based polymeric ionic liquid (p-Poly-(MMA-IL) FP) for analysis of multi-class antibiotic drugs under the p-TFME analytical device procedure was successfully achieved with limited sample volume and organic solvent, fast extraction, and feasible in daily analysis. The detection concentration and relative RSD of multi-class antibiotics determined in various environmental water samples by the proposed method (n = 5) were within 0.44 μg L-1 - 54.41 μg L-1 and 0.69%-15.56%, respectively. These results signified the potential of the p-Poly-(MMA-IL) FP-TFME device as an efficient, sensitive and environmentally friendly approach for analysing antibiotics.

Keywords: Environmental water samples; Liquid chromatography-mass spectrometry; Multi-class antibiotic drugs; Paper-based materials; Polymeric ionic liquid; Thin-film microextraction.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

MeSH terms

LinkOut - more resources