Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Aug;71(8):437-446.
doi: 10.1007/s11748-022-01898-0. Epub 2022 Dec 16.

Is the QRS duration useful for determining the optimal timing of pulmonary valve replacement after tetralogy of Fallot repair?

Affiliations

Is the QRS duration useful for determining the optimal timing of pulmonary valve replacement after tetralogy of Fallot repair?

Junya Sugiura et al. Gen Thorac Cardiovasc Surg. 2023 Aug.

Abstract

Objectives: In pulmonary valve replacement (PVR) after tetralogy of Fallot (TOF) repair, the right ventricular end-diastolic and end-systolic volume index (RVEDVI and RVESVI) of cardiac magnetic resonance imaging (cMRI) are often used as indicators of the RV volume. We examined the utility of QRS duration, cardiothoracic ratio (CTR), and plasma brain natriuretic peptide (BNP) as indicators of the appropriate timing of cMRI to assess the RV volume and function before PVR.

Methods: We assessed the correlation of QRS duration, CTR, and BNP with RVEDVI and RVESVI on cMRI in 26 patients after TOF repair. Fifteen underwent PVR (age, 45.2 ± 11.4 years). Twelve underwent post-PVR cMRI. The RV volume change from before to after PVR was investigated.

Results: QRS duration, BNP, and CTR were positively correlated with RVEDVI and RVESVI after TOF repair. The post-PVR QRS duration was also positively correlated with post-PVR RVEDVI (p = 0.017) and RVESVI (p = 0.001). From before to after PVR, in 5 cases with QRS duration ≤ 160 ms, the QRS duration decreased from 110.4 ± 28.9 to 101.8 ± 30.5 ms (p = 0.063). Both RVEDVI and RVESVI decreased to the normal range in 4 of 5 cases. In contrast, in 7 cases with QRS duration > 160 ms, the QRS duration decreased from 183.0 ± 17.4 to 160.3 ± 23.8 ms (p = 0.013); however, RVESVI did not normalize in 6 of 7 cases.

Conclusions: A prolonged QRS duration is a useful marker of RVEDVI and RVESVI enlargement after TOF repair. We recommend performing cMRI before the QRS duration reaches 160 ms due to normalization of the RV volume after PVR.

Keywords: Cardiac magnetic resonance imaging; Pulmonary valve replacement; QRS duration; Right ventricle; Tetralogy of Fallot.

PubMed Disclaimer

References

    1. Dehaki MG, Al-Dairy A, Rezaei Y, Omrani G, Jalali AH, Javadikasgari H, et al. Mid-term outcomes of mechanical pulmonary valve replacement: a single-institutional experience of 396 patients. Gen Thorac Cardiovasc Surg. 2019;67:289–96. - DOI - PubMed
    1. Geva T. Indications and timing of pulmonary valve replacement after tetralogy of Fallot repair. Pediatr Card Surg Annu. 2006;9:11–22.
    1. Helbing WA, Niezen RA, Cessie SLE, Van Der Geest RJ, Ottenkamp J, De Roos A. Right ventricular diastolic function in children with pulmonary regurgitation after repair of tetralogy of Fallot: volumetric evaluation by magnetic resonance velocity mapping. J Am Coll Cardiol. 1997;28:1827–35. - DOI
    1. Davlouros PA, Kilner PJ, Hornung TS, Li W, Francis JM, Moon JCC, et al. Right ventricular function in adults with repaired tetralogy of Fallot assessed with cardiovascular magnetic resonance imaging: detrimental role of right ventricular outflow aneurysms or akinesia and adverse right-to-left ventricular interaction. J Am Coll Cardiol. 2002;40:2044–52. - DOI - PubMed
    1. Therrien J, Provost Y, Merchant N, Williams W, Colman J, Webb G. Optimal timing for pulmonary valve replacement in adults after tetralogy of Fallot repair. Am J Cardiol. 2005;95:779–82. - DOI - PubMed

MeSH terms

LinkOut - more resources