Tell-a provider about tele: Reducing overuse of telemetry across 10 hospitals in a safety net system
- PMID: 36567609
- DOI: 10.1002/jhm.13030
Tell-a provider about tele: Reducing overuse of telemetry across 10 hospitals in a safety net system
Abstract
Background: Telemetry is often a scarce resource at hospitals and is important for arrhythmia and myocardial ischemia detection. Overuse of telemetry monitoring leads to alarm fatigue resulting in failure to respond to arrhythmias, patient harm, and possible unnecessary testing.
Methods: This quality improvement initiative was implemented across NYC Health and Hospitals, an 11-hospital urban safety net system. The electronic health record intervention involved the addition of a mandatory indication in the telemetry order and a best practice advisory (BPA) that would fire after the recommended time period for reassessment had passed.
Results: The average telemetry hours per patient encounter went from 60.1 preintervention to 48.4 postintervention, a 19.5% reduction (p < .001). When stratified by the 11 hospitals, decreases ranged from 9% to 30%. The BPA had a 53% accept rate and fired 52,682 times, with 27,938 "discontinue telemetry" orders placed. The true accept rate was 50.4%, as there was a 2.6% 24-h reorder rate. There was variation based on clinician specialty and clinician type (attending, fellow, resident, physician associate, nurse practitioner).
Conclusion: We successfully reduced telemetry monitoring across a multisite safety net system using solely an electronic health record (EHR) intervention. This expands on previous telemetry monitoring reduction initiatives using EHR interventions at single academic sites. Further study is needed to investigate variation across clinician type, specialty, and post-acute sites.
© 2022 Society of Hospital Medicine.
Similar articles
-
Harnessing the Electronic Health Record to Actively Support Providers with Guideline-Directed Telemetry Use.Appl Clin Inform. 2021 Oct;12(5):996-1001. doi: 10.1055/s-0041-1736338. Epub 2021 Oct 27. Appl Clin Inform. 2021. PMID: 34706394 Free PMC article.
-
Assessment of a Targeted Electronic Health Record Intervention to Reduce Telemetry Duration: A Cluster-Randomized Clinical Trial.JAMA Intern Med. 2019 Jan 1;179(1):11-15. doi: 10.1001/jamainternmed.2018.5859. JAMA Intern Med. 2019. PMID: 30535345 Free PMC article. Clinical Trial.
-
Reducing 25-Hydroxyvitamin D Testing in a Large, Urban Safety Net System.J Gen Intern Med. 2023 Aug;38(10):2326-2332. doi: 10.1007/s11606-023-08201-8. Epub 2023 May 2. J Gen Intern Med. 2023. PMID: 37131103 Free PMC article.
-
Update to Practice Standards for Electrocardiographic Monitoring in Hospital Settings: A Scientific Statement From the American Heart Association.Circulation. 2017 Nov 7;136(19):e273-e344. doi: 10.1161/CIR.0000000000000527. Epub 2017 Oct 3. Circulation. 2017. PMID: 28974521 Review.
-
[Telemetry in the clinical setting].Herzschrittmacherther Elektrophysiol. 2008 Sep;19(3):146-54. doi: 10.1007/s00399-008-0017-2. Epub 2008 Oct 25. Herzschrittmacherther Elektrophysiol. 2008. PMID: 18956161 Review. German.
Cited by
-
Evaluation of a Clinical Decision Support Tool to Guide Adoption of the American Heart Association Telemetry Monitoring Practice Standards.J Am Heart Assoc. 2024 May 7;13(9):e031523. doi: 10.1161/JAHA.123.031523. Epub 2024 Apr 30. J Am Heart Assoc. 2024. PMID: 38686881 Free PMC article.
-
Optimizing Decision Support Alerts to Reduce Telemetry Duration: A Multicenter Evaluation.Appl Clin Inform. 2024 Oct;15(5):860-868. doi: 10.1055/s-0044-1789574. Epub 2024 Oct 23. Appl Clin Inform. 2024. PMID: 39442537
-
Reducing Overuse of 3-Day Repeat Type and Screen Testing across an 11-Hospital Safety Net System.J Gen Intern Med. 2024 Jan;39(1):13-18. doi: 10.1007/s11606-023-08300-6. Epub 2023 Jul 10. J Gen Intern Med. 2024. PMID: 37429975 Free PMC article.
References
REFERENCES
-
- Yeow RY, Strohbehn GW, Kagan CM, et al. Eliminating inappropriate telemetry monitoring: an evidence-based implementation guide. JAMA Intern Med. 2018;178(7):971-978.
-
- Graham KC, Cvach M. Monitor alarm fatigue: standardizing use of physiological monitors and decreasing nuisance alarms. Am J Crit Care. 2010;19(1):28-34.
-
- Atzema C, Schull MJ, Borgundvaag B, Slaughter GRD, Lee CK. ALARMED: adverse events in low-risk patients with chest pain Receiving continuous electrocardiographic monitoring in the emergency department: a pilot study. Am J Emerg Med. 2006;24(1):62-67.
-
- Benjamin EM, Klugman RA, Luckmann R, Fairchild DG, Abookire SA. Impact of cardiac telemetry on patient safety and cost. Am J Manag Care. 2013;19(6):225-232.
-
- Cvach M. Monitor alarm fatigue: an integrative review. Biomed Instrum Technol. 2012;46(4):268-277.