Tell-a provider about tele: Reducing overuse of telemetry across 10 hospitals in a safety net system
- PMID: 36567609
- DOI: 10.1002/jhm.13030
Tell-a provider about tele: Reducing overuse of telemetry across 10 hospitals in a safety net system
Abstract
Background: Telemetry is often a scarce resource at hospitals and is important for arrhythmia and myocardial ischemia detection. Overuse of telemetry monitoring leads to alarm fatigue resulting in failure to respond to arrhythmias, patient harm, and possible unnecessary testing.
Methods: This quality improvement initiative was implemented across NYC Health and Hospitals, an 11-hospital urban safety net system. The electronic health record intervention involved the addition of a mandatory indication in the telemetry order and a best practice advisory (BPA) that would fire after the recommended time period for reassessment had passed.
Results: The average telemetry hours per patient encounter went from 60.1 preintervention to 48.4 postintervention, a 19.5% reduction (p < .001). When stratified by the 11 hospitals, decreases ranged from 9% to 30%. The BPA had a 53% accept rate and fired 52,682 times, with 27,938 "discontinue telemetry" orders placed. The true accept rate was 50.4%, as there was a 2.6% 24-h reorder rate. There was variation based on clinician specialty and clinician type (attending, fellow, resident, physician associate, nurse practitioner).
Conclusion: We successfully reduced telemetry monitoring across a multisite safety net system using solely an electronic health record (EHR) intervention. This expands on previous telemetry monitoring reduction initiatives using EHR interventions at single academic sites. Further study is needed to investigate variation across clinician type, specialty, and post-acute sites.
© 2022 Society of Hospital Medicine.
References
REFERENCES
-
- Yeow RY, Strohbehn GW, Kagan CM, et al. Eliminating inappropriate telemetry monitoring: an evidence-based implementation guide. JAMA Intern Med. 2018;178(7):971-978.
-
- Graham KC, Cvach M. Monitor alarm fatigue: standardizing use of physiological monitors and decreasing nuisance alarms. Am J Crit Care. 2010;19(1):28-34.
-
- Atzema C, Schull MJ, Borgundvaag B, Slaughter GRD, Lee CK. ALARMED: adverse events in low-risk patients with chest pain Receiving continuous electrocardiographic monitoring in the emergency department: a pilot study. Am J Emerg Med. 2006;24(1):62-67.
-
- Benjamin EM, Klugman RA, Luckmann R, Fairchild DG, Abookire SA. Impact of cardiac telemetry on patient safety and cost. Am J Manag Care. 2013;19(6):225-232.
-
- Cvach M. Monitor alarm fatigue: an integrative review. Biomed Instrum Technol. 2012;46(4):268-277.