Does Ultrasound Guidance Provide Pain Relief During Intrauterine Contraceptive Device Insertion? A Systematic Review and Meta-Analysis of Randomized Controlled Trials
- PMID: 36583454
- DOI: 10.1002/jum.16166
Does Ultrasound Guidance Provide Pain Relief During Intrauterine Contraceptive Device Insertion? A Systematic Review and Meta-Analysis of Randomized Controlled Trials
Abstract
Objective: To evaluate ultrasound guidance effect in pain relief during intrauterine device (IUD) insertion.
Methods: Four different databases were searched from inception till June 2022. We selected randomized controlled trials (RCTs) that compared transabdominal ultrasound guidance versus traditional non-guided IUD insertion among women undergoing IUD placement for contraception. We used Revman software during performing our meta-analysis. Our primary outcome was the pain score during IUD insertion as evaluated by the Visual Analog Scale (VAS). Our secondary outcomes were the procedure insertion time, satisfaction, and incidences of complications and misplaced IUDs.
Results: Seven RCTs were retrieved with a total number of 1267 patients. There was a significant reduction in the VAS pain score during IUD insertion among the ultrasound-guided group (MD = -1.91, 95% CI [-3.08, -0.73], P = .001). The procedure insertion time was significantly shorter within the ultrasound guidance group compared with the control group (MD = -1.35, 95% CI [-1.81, -0.88], P < .001). Moreover, more women were significantly satisfied with the procedure among the ultrasound-guided group (P < .001). In addition, ultrasound-guided IUD insertion was linked to significant decline in incidences of complications and misplaced IUDs.
Conclusion: Ultrasound guidance can be used as a modified technique during IUD insertion as it decreases pain, procedure time, and rates of complications and misplaced IUDs with better patient satisfaction.
Keywords: intrauterine device; pain; ultrasound guidance; ultrasound-guided.
© 2022 American Institute of Ultrasound in Medicine.
References
-
- Connolly CT, Fox NS. Incidence and risk factors for a malpositioned intrauterine device detected on three-dimensional ultrasound within eight weeks of placement. J Ultrasound Med 2022; 41:1525-1536.
-
- Buhling KJ, Zite NB, Lotke P, Black K, INTRA Writing Group. Worldwide use of intrauterine contraception: a review. Contraception 2014; 89:162-173.
-
- Peipert JF, Zhao Q, Allsworth JE, et al. Continuation and satisfaction of reversible contraception. Obstet Gynecol 2011; 117:1105-1113.
-
- Ortiz ME, Croxatto HB, Bardin CW. Mechanisms of action of intrauterine devices. Obstet Gynecol Surv 1996; 51:S42-S51.
-
- Akintomide H, Brima N, Sewell RDE, Stephenson JM. Patients' experiences and providers' observations on pain during intrauterine device insertion. Eur J Contracept Reprod Health Care 2015; 20:319-326.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical