Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jan;39(1):245-254.
doi: 10.1007/s10554-022-02717-6. Epub 2022 Aug 28.

Radiation dose reduction in the setting of cryoballoon ablation for atrial fibrillation: the value of optimized fluoroscopy settings and intracardiac echocardiography

Affiliations

Radiation dose reduction in the setting of cryoballoon ablation for atrial fibrillation: the value of optimized fluoroscopy settings and intracardiac echocardiography

Vedran Velagic et al. Int J Cardiovasc Imaging. 2023 Jan.

Abstract

Cryoballoon (CB) has proven to be very effective in the percutaneous treatment of atrial fibrillation (AF). CB ablation is still hampered by X-ray exposure and the doses applied are consistently higher if compared to radiofrequency ablation. All patients who underwent CB ablation between 2015 and 2020 were analysed. Intracardiac echography was consistently used for transeptal puncture. To demonstrate the differences in radiation exposure 3 groups of 50 consecutive patients were selected. In the first group (G1) 3D rotational angiography (3DRA) was used as an intraprocedural imaging method. In the second group (G2), traditional X-ray imaging was used and frame rates both for fluoro and cine modes of diascopy were lowered. In the third group (G3) only 2-3 frames per second were used, cine mode was abandoned and the grid was removed from the X-ray detector. A total of 150 patients were included (76% males, mean age 57.3 ± 11.5 years). A dramatic reduction of radiation dose was obtained from 9585 ± 5610 µGy/m2 in G1 to 2469 ± 2002 µGy/m2 in G2 and finally 227.1 ± 360 µGy/m2 in G3 (p < 0.0001). There was also a significant decrease of procedural and fluoroscopy times. No difference in major complications and midterm outcomes was found between the groups. By following a few relatively simple steps (omitting the pre-procedural imaging, removing grid from the X-ray detector and using very low frame rates) CB ablation could be performed with ultralow radiation exposure without compromising the safety of efficacy of the procedure.

Keywords: Atrial fibrillation; Catheter ablation; Cryoballoon; Radiation dose reduction.

PubMed Disclaimer

References

    1. Hindricks G, Potpara T, Dagres N, Arbelo E, Bax JJ, Blomström-Lundqvist C, ESC Scientific Document Group et al (2021) 2020 ESC guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): the task force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology (ESC) developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC. Eur Heart J 42(5):373–498 - DOI
    1. Velagić V, de Asmundis C, Mugnai G, Hünük B, Hacioğlu E, Ströker E et al (2017) Learning curve using the second-generation cryoballoon ablation. J Cardiovasc Med (Hagerstown) 18(7):518–527 - DOI
    1. Aryana A, Singh SM, Kowalski M, Pujara DK, Cohen AI, Singh SK et al (2015) Acute and long-term outcomes of catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: a multicenter experience. J Cardiovasc Electrophysiol 26(8):832–839 - DOI
    1. Murray MI, Arnold A, Younis M, Varghese S, Zeiher AM (2018) Cryoballoon versus radiofrequency ablation for paroxysmal atrial fibrillation: a meta-analysis of randomized controlled trials. Clin Res Cardiol 107:658–669 - DOI
    1. Fortuni F, Casula M, Sanzo A, Angelini F, Cornara S, Somaschini A et al (2020) Meta-analysis comparing cryoballoon versus radiofrequency as first ablation procedure for atrial fibrillation. Am J Cardiol 125(8):1170–1179 - DOI

MeSH terms

LinkOut - more resources