Low-Dose vs Standard Warfarin After Mechanical Mitral Valve Replacement: A Randomized Trial

Collaborators, Affiliations
Randomized Controlled Trial

Low-Dose vs Standard Warfarin After Mechanical Mitral Valve Replacement: A Randomized Trial

Michael W A Chu et al. Ann Thorac Surg. 2023 Apr.

Abstract

Background: Current guidelines recommend a target international normalized ratio (INR) range of 2.5 to 3.5 in patients with a mechanical mitral prosthesis. The Prospective Randomized On-X Anticoagulation Clinical Trial (PROACT) Mitral randomized controlled noninferiority trial assessed safety and efficacy of warfarin at doses lower than currently recommended in patients with an On-X (Artivion, Inc) mechanical mitral valve.

Methods: After On-X mechanical mitral valve replacement, followed by at least 3 months of standard anticoagulation, 401 patients at 44 North American centers were randomized to low-dose warfarin (target INR, 2.0-2.5) or standard-dose warfarin (target INR, 2.5-3.5). All patients were prescribed aspirin, 81 mg daily, and encouraged to use home INR testing. The primary end point was the sum of the linearized rates of thromboembolism, valve thrombosis, and bleeding events. The design was based on an expected 7.3% event rate and 1.5% noninferiority margin.

Results: Mean patient follow-up was 4.1 years. Mean INR was 2.47 and 2.92 (P <.001) in the low-dose and standard-dose warfarin groups, respectively. Primary end point rates were 11.9% per patient-year in the low-dose group and 12.0% per patient-year in the standard-dose group (difference, -0.07%; 95% CI, -3.40% to 3.26%). The CI >1.5%, thus noninferiority was not achieved. Rates (percentage per patient-year) of the individual components of the primary end point were 2.3% vs 2.5% for thromboembolism, 0.5% vs 0.5% for valve thrombosis, and 9.13% vs 9.04% for bleeding.

Conclusions: Compared with standard-dose warfarin, low-dose warfarin did not achieve noninferiority for the composite primary end point. (PROACT Clinicaltrials.gov number, NCT00291525).