The effect of fibrin polymerization inhibitors on quantitative measurements of plasma fibrinogen
- PMID: 3661500
- DOI: 10.1093/ajcp/88.4.490
The effect of fibrin polymerization inhibitors on quantitative measurements of plasma fibrinogen
Abstract
A number of reports have highlighted discrepancies between the DuPont aca and fibrometer-based methods for quantitating plasma fibrinogen levels. Although many authors have suggested that the presence of fibrin(ogen) degradation products are in some way responsible for the discrepancies, no direct test of this hypothesis has been carried out. In this report, the authors demonstrate that inhibitors of fibrin monomer polymerization have different effects on the aca and fibrometer assays of fibrinogen. Fibrin polymerization inhibitors allow short soluble fibrin polymers to assemble that can scatter light and are therefore detected by the aca method. However, these short polymers do not gel and thus are not detected by the fibrometer. Therefore, the fibrometer method gives lower fibrinogen values than the aca in the presence of fibrin polymerization inhibitors. The authors also assayed plasma from a patient whose fibrinogen did not polymerize normally and therefore was not measurable by the fibrometer assay. The dysfibrinogenemic plasma assayed by the aca method recorded normal fibrinogen levels. In conclusion, the DuPont aca fibrinogen assay is insensitive to alterations of fibrin polymerization whether from inhibitors or a defective fibrinogen molecule.
Similar articles
-
Inhibition of fibrin monomer polymerization by Bence Jones protein in a patient with primary amyloidosis.Acta Haematol. 1989;81(3):160-5. doi: 10.1159/000205551. Acta Haematol. 1989. PMID: 2496565
-
The measurement of fibrinogen by the DuPont aca and Dade methods in patients receiving streptokinase infusions.Am J Clin Pathol. 1985 Oct;84(4):526-9. doi: 10.1093/ajcp/84.4.526. Am J Clin Pathol. 1985. PMID: 4036883
-
[A method of determining the anti-, de- and fibrin-polymerization activity of the blood plasma].Lab Delo. 1990;(7):53-7. Lab Delo. 1990. PMID: 1699071 Russian.
-
The use of soluble fibrin in evaluating the acute and chronic hypercoagulable state.Thromb Haemost. 1999 Aug;82(2):673-83. Thromb Haemost. 1999. PMID: 10605767 Review.
-
Fibrin degradation products, fibrin monomer and soluble fibrin in disseminated intravascular coagulation.Semin Thromb Hemost. 2001 Dec;27(6):657-66. doi: 10.1055/s-2001-18870. Semin Thromb Hemost. 2001. PMID: 11740689 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources