Robot-assisted versus navigated transpedicular spine fusion: A comparative study
- PMID: 36649651
- DOI: 10.1002/rcs.2500
Robot-assisted versus navigated transpedicular spine fusion: A comparative study
Abstract
Background: The aim of this study was to compare the intraoperative and postoperative outcomes between a robot-assisted versus a navigated transpedicular fusion technique.
Methods: This retrospective analysis included patients who underwent transpedicular posterior fusion of the spine due to trauma, pyogenic spondylodiscitis and osteoporosis. Surgery was done either with a robot-assisted or a percutaneous navigated transpedicular fusion technique. The outcome analysis included the duration of surgery, the radiation exposure, the postoperative screw position and complications.
Results: A total of 60 patients were operated and 491 screws were analysed. No statistical difference was seen in the applied cumulative effective radiation dose per patient. The radiological assessment revealed a more accurate screw placement with robot assistance. A learning curve could be observed in robot-assisted fusion.
Conclusion: Robot-assisted and navigated transpedicular fusion techniques are both effective and safe. Robot-assisted transpedicular spine fusion goes along with higher placement accuracy but its implementation needs an adequate learning curve.
Keywords: navigation; robot-assisted spine surgery; spine fusion; transpedicular screw positioning.
© 2023 John Wiley & Sons Ltd.
References
REFERENCES
-
- Gelalis ID, Paschos NK, Pakos EE, et al. Accuracy of pedicle screw placement: A systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J. 2012;21(2):247-255. https://doi.org/10.1007/s00586-011-2011-3
-
- Odate S, Fujibayashi S, Otsuki B, et al. Reoperation for misplaced pedicle serves: A multicenter retrospective study. Spine. 2022;47(21):1525-1531. https://doi.org/10.1097/BRS.0000000000004398
-
- Gautschi OP, Schatlo B, Schaller K, Tessitore E. Clinically relevant complications related to pedicle screw placement in thoracolumbar surgery and their management: a literature review of 35,630 pedicle screws. Neurosurg Focus. 2011;31(4):E8. https://doi.org/10.3171/2011.7.FOCUS11168
-
- Podolsky DJ, Martin AR, Whyne CM, Massicotte EM, Hardisty MR, Ginsberg HJ. Exploring the role of 3-dimensional simulation in surgical training: feedback from a pilot study. J Spinal Disord Tech. 2010;23(8):e70-e74. https://doi.org/10.1097/BSD.0b013e3181d345cb
-
- Hu X, Ohnmeiss DD, Lieberman IH. Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients. Eur Spine J. 2013;22(3):661-666. https://doi.org/10.1007/s00586-012-2499-1
MeSH terms
LinkOut - more resources
Full Text Sources