Protein mass measurement by mass spectrometry is complicated by wide isotopic distributions that result from incorporation of heavy isotopes of C, H, N, O, and S, thereby limiting signal-to-noise ratio (SNR) and accurate intact mass determination, particularly for larger proteins [Fenselau et al. Anal. Chem. 1983, 55 (2), 353-356]. Observation of the monoisotopic mass-to-charge ratio (m/z) is the simplest and most accurate way to determine intact protein mass, but as mass increases, the relative abundance of the monoisotopic peak becomes so low that it is often undetectable. Here, we used an isotopically depleted growth medium to culture bacterial cells (Escherichia coli), resulting in isotopically depleted proteins. Isotopically depleted proteins show increased sequence coverage, mass measurement accuracy, and increased S/N of the monoisotopic peak by Fourier transform ion cyclotron resonance mass spectrometry analysis. We then grew Caenorhabditis elegans cells in a medium containing living isotopically depleted E. coli cells, thereby producing the first isotopically depleted eukaryotic proteins. This is the first time isotopic depletion has been implemented for four isotopes (1H, 12C, 14N, and 16O), resulting in the highest degree of depletion ever used for protein analysis and further improving MS analysis.
Similar articles
-
Isotope Depletion Mass Spectrometry (ID-MS) for Accurate Mass Determination and Improved Top-Down Sequence Coverage of Intact Proteins.J Am Soc Mass Spectrom. 2020 Mar 4;31(3):700-710. doi: 10.1021/jasms.9b00119. Epub 2020 Feb 11. J Am Soc Mass Spectrom. 2020. PMID: 32003978
-
Counting individual sulfur atoms in a protein by ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry: experimental resolution of isotopic fine structure in proteins.Proc Natl Acad Sci U S A. 1998 Sep 29;95(20):11532-7. doi: 10.1073/pnas.95.20.11532. Proc Natl Acad Sci U S A. 1998. PMID: 9751700 Free PMC article.
-
Combination of liquid chromatography-Fourier transform ion cyclotron resonance-mass spectrometry with 13C-labeling for chemical assignment of sulfur-containing metabolites in onion bulbs.Anal Chem. 2013 Feb 5;85(3):1310-5. doi: 10.1021/ac302733c. Epub 2013 Jan 17. Anal Chem. 2013. PMID: 23327693
-
Liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometry (LC-FTICR MS): an early overview.Anal Bioanal Chem. 2004 Aug;379(7-8):1013-24. doi: 10.1007/s00216-004-2675-1. Epub 2004 Jun 23. Anal Bioanal Chem. 2004. PMID: 15221183 Review.
-
Fourier transform ion cyclotron resonance mass spectrometry at the true cyclotron frequency.Mass Spectrom Rev. 2022 Mar;41(2):314-337. doi: 10.1002/mas.21681. Epub 2021 Jan 18. Mass Spectrom Rev. 2022. PMID: 33462876 Review.
Cited by
-
Selected Ion Extraction of Peptides with Heavy Isotopes and Hydrogen Loss Reduces the Type II Error in Plasma Proteomics.ACS Omega. 2025 Jan 2;10(1):281-293. doi: 10.1021/acsomega.4c05624. eCollection 2025 Jan 14. ACS Omega. 2025. PMID: 39829503 Free PMC article.
-
Comparison of the Human Plasma Peptides from the Fit of Fragmentation Spectra versus Accurate Monoisotopic Precursor Mass.ACS Omega. 2025 Mar 10;10(11):10796-10811. doi: 10.1021/acsomega.4c06211. eCollection 2025 Mar 25. ACS Omega. 2025. PMID: 40160755 Free PMC article.
-
Isotopic Depletion Increases the Spatial Resolution of FPOP Top-Down Mass Spectrometry Analysis.Anal Chem. 2024 Jan 30;96(4):1478-1487. doi: 10.1021/acs.analchem.3c03759. Epub 2024 Jan 16. Anal Chem. 2024. PMID: 38226459 Free PMC article.
-
Trypsin Digestion Conditions of Human Plasma for Observation of Peptides and Proteins from Tandem Mass Spectrometry.ACS Omega. 2024 Sep 24;9(40):41343-41354. doi: 10.1021/acsomega.4c03955. eCollection 2024 Oct 8. ACS Omega. 2024. PMID: 39398168 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources