Effect of Magnetic Resonance Imaging at 1.5 T and 3 T on Temperature and Bond Strength of Orthodontic Bands with Welded Tubes: An In Vitro Study

Affiliations

Effect of Magnetic Resonance Imaging at 1.5 T and 3 T on Temperature and Bond Strength of Orthodontic Bands with Welded Tubes: An In Vitro Study

Maria Francesca Sfondrini et al. Materials (Basel). .

Abstract

Magnetic resonance imaging (MRI) is a widely used diagnostic technique. Patients wearing orthodontic devices are often requested to remove their appliances before an MRI exam, even when the exam involves anatomical areas far from the head, in order to prevent the heating and detachment of the appliances. The present report aims to evaluate changes in temperature and adhesive forces of molar bands after MRI at two different strength outputs. Sixty stainless steel molar bands were bonded on permanent human upper molars using two different cements: Unitek Multi-Cure Glass Ionomer Band Cement (3M Unitek, Monrovia, CA, USA) and Transbond Plus Light Cure Band Adhesive (3M Unitek). Appliances were subjected to MRI with two different strengths (1.5 Tesla and 3 Tesla). Tubes and band temperature was measured before and after MRI. Subsequently, the shear bond strength (SBS) test was calculated. Data underwent statistical analysis (p < 0.05). After MRI, molar bands exhibited significant heating, even though not clinically relevant, with a temperature increase ranging between 0.48 °C and 1.25 °C (p < 0.05). SBS did not show significant differences (p > 0.05). The present study suggests that, under MRI, the molar bands tested are safe; therefore, their removal could be not recommended for non-head and neck MRI exams. Removal would be necessary just in artifact risk areas.

Keywords: composite cement; glass ionomer cement; molar bands.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
Tube temperature variation (°C) for each material before and after the 1.5 T and 3 T MRIs.
Figure 2
Figure 2
Band temperature variations (°C) for each material before and after the 1.5 T and 3 T MRIs.

References

    1. Reda R., Zanza A., Mazzoni A., Cicconetti A., Testarelli L., Di Nardo D. An Update of the Possible Applications of Magnetic Resonance Imaging (MRI) in Dentistry: A Literature Review. J. Imaging. 2021;7:75. doi: 10.3390/jimaging7050075. - DOI - PMC - PubMed
    1. Chockattu S.J., Suryakant D.B., Thakur S. Unwanted effects due to interactions between dental materials and magnetic resonance imaging: A review of the literature. Restor. Dent. Endod. 2018;43:39. doi: 10.5395/rde.2018.43.e39. - DOI - PMC - PubMed
    1. Poorsattar-Bejeh Mir A., Rahmati-Kamel M. Should the orthodontic brackets always be removed prior to magnetic resonance imaging (MRI)? J. Oral Biol. Craniofac. Res. 2016;6:142–152. doi: 10.1016/j.jobcr.2015.08.007. - DOI - PMC - PubMed
    1. Görgülü S., Ayyildiz S., Kamburoglu K., Gökçe S., Ozen T. Effect of orthodontic brackets and different wires on radiofrequency heating and magnetic field interactions during 3-T MRI. Dentomaxillofac. Radiol. 2014;43:20130356. doi: 10.1259/dmfr.20130356. - DOI - PMC - PubMed
    1. Dalili Kajan Z., Khademi J., Alizadeh A., Babaei Hemmaty Y., Atrkar Roushan Z. A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. Imaging Sci. Dent. 2015;45:159–168. doi: 10.5624/isd.2015.45.3.159. - DOI - PMC - PubMed

LinkOut - more resources