Associations among preoperative transthoracic echocardiography variables and cerebral near-infrared spectroscopy values at baseline before anesthesia in patients undergoing cardiac surgery: a retrospective observational study
- PMID: 36692544
- DOI: 10.1007/s00380-023-02233-0
Associations among preoperative transthoracic echocardiography variables and cerebral near-infrared spectroscopy values at baseline before anesthesia in patients undergoing cardiac surgery: a retrospective observational study
Abstract
Cerebral tissue oximetry with near-infrared spectroscopy (NIRS) is used to monitor cerebral oxygenation during cardiac surgery. To date, reduced baseline cerebral NIRS values have been attributed to reduced cerebral blood flow primarily based on a significant positive correlation between left ventricular ejection fraction (LVEF) and baseline rSO2 measured with the INVOS 5100C oximeter. Reportedly, however, rSO2, but not StO2 measured with the FORESIGHT Elite oximeter, correlated with LVEF. We, thus, investigated associations among baseline NIRS values measured with three different oximeters before anesthesia for cardiac surgery and preoperative transthoracic echocardiography (TTE) variables, including LVEF, to examine whether there are inter-device differences in associations among baseline NIRS values and TTE variables. Using Spearman's correlation coefficient, we retrospectively investigated associations among 15 preoperative TTE variables, including LVEF, and baseline NIRS values, including rSO2, StO2, and TOI with the NIRO-200NX oximeter in 1346, 515, and 301 patients, respectively. Only rSO2 (p < 0.00001), but not TOI or StO2 (p > 0.05), positively correlated with LVEF. On the other hand, baseline rSO2, TOI, and StO2 consistently, negatively correlated with the left atrial diameter index (LADI), early diastolic transmitral flow velocity (E), E-to-early diastolic mitral annular velocity ratio (E/e'), estimated right ventricular systolic pressure (eRVP), and inferior vena cava diameter index (IVCDI) (p < 0.0005 to p < 0.00001). Because all of these five TTE variables could be positively associated with right as well as left ventricular filling pressure, our results indicated that reduced baseline NIRS values were consistently associated not with reduced LVEF but with TTE findings indicative of elevated biventricular filling pressure. Our data suggest that regional venous congestion greatly contributes to reduced baseline NIRS values in patients undergoing cardiac surgery.
Keywords: Cardiac surgery; Cerebral blood flow; Near-infrared spectroscopy; Transthoracic echocardiography; Venous congestion.
© 2023. Springer Nature Japan KK, part of Springer Nature.
Similar articles
-
A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients.Paediatr Anaesth. 2005 Jun;15(6):495-503. doi: 10.1111/j.1460-9592.2005.01488.x. Paediatr Anaesth. 2005. PMID: 15910351
-
B-Type Natriuretic Peptide and Hemoglobin are Two Major Factors Significantly Associated With Baseline Cerebral Oxygen Saturation Measured Using the INVOS Oximeter in Patients Undergoing Off-Pump Coronary Artery Bypass Graft Surgery.J Cardiothorac Vasc Anesth. 2018 Feb;32(1):187-196. doi: 10.1053/j.jvca.2017.04.018. Epub 2017 Apr 13. J Cardiothorac Vasc Anesth. 2018. PMID: 28778770
-
The Correlation of Two Cerebral Saturation Monitors With Jugular Bulb Oxygen Saturation in Children Undergoing Cardiopulmonary Bypass for Congenital Heart Surgery.J Intensive Care Med. 2017 Dec;32(10):603-608. doi: 10.1177/0885066616663649. Epub 2016 Aug 15. J Intensive Care Med. 2017. PMID: 27530512
-
[Near Infrared Spectroscopy for cerebral monitoring during cardiovascular surgery].Clin Ter. 2010;161(6):549-53. Clin Ter. 2010. PMID: 21181086 Review. Italian.
-
American Society for Enhanced Recovery and Perioperative Quality Initiative Joint Consensus Statement on the Role of Neuromonitoring in Perioperative Outcomes: Cerebral Near-Infrared Spectroscopy.Anesth Analg. 2020 Nov;131(5):1444-1455. doi: 10.1213/ANE.0000000000005081. Anesth Analg. 2020. PMID: 33079868 Review.
Cited by
-
The role of E-wave velocity in predicting early left ventricular dysfunction and significant decline in left ventricular ejection fraction after mitral valve repair for severe chronic primary mitral regurgitation.Heart Vessels. 2025 Apr;40(4):320-331. doi: 10.1007/s00380-024-02468-5. Epub 2024 Oct 8. Heart Vessels. 2025. PMID: 39375196
References
-
- Yoshitani K, Kawaguchi M, Ishida K, Maekawa K, Miyawaki H, Tanaka S, Uchino H, Kakinohana M, Koide Y, Yokota M, Okamoto H, Nomura M (2019) Guidelines for the use of cerebral oximetry by near-infrared spectroscopy in cardiovascular anesthesia: a report by the cerebrospinal Division of the Academic Committee of the Japanese Society of Cardiovascular Anesthesiologists (JSCVA). J Anesth 33:167–196 - DOI - PubMed
-
- Yamamoto M, Hayashida M, Kakemizu-Watanabe M, Ando N, Mukaida H, Kawagoe I, Yusuke S, Inada E (2018) B-type natriuretic peptide and hemoglobin are two major factors significantly associated with baseline cerebral oxygen saturation measured using the INVOS oximeter in patients undergoing off-pump coronary artery bypass graft surgery. J Cardiothorac Vasc Anesth 32:187–196 - DOI - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical