. 2023 Jan 26;18(1):e0281017.
doi: 10.1371/journal.pone.0281017. eCollection 2023.

Evaluation of corneal biomechanical properties using the ocular response analyzer and the dynamic Scheimpflug-Analyzer Corvis ST in high pressure and normal pressure open-angle glaucoma patients

Affiliations

Evaluation of corneal biomechanical properties using the ocular response analyzer and the dynamic Scheimpflug-Analyzer Corvis ST in high pressure and normal pressure open-angle glaucoma patients

Lisa Ramm et al. PLoS One. .

Abstract

Purpose: To characterize differences in corneal biomechanics in high (HPG) and normal pressure (NPG) primary open-angle glaucoma, and its association to disease severity.

Methods: Corneal biomechanical properties were measured using the Ocular Response Analyzer (ORA) and the dynamic Scheimpflug-Analyzer Corvis ST (CST). Disease severity was functionally assessed by automated perimetry (Humphrey field analyzer) and structurally with the Heidelberg Retina Tomograph. To avoid a possible falsification by intraocular pressure, central corneal thickness and age, which strongly influence ORA and CST measurements, group matching was performed. Linear mixed models and generalized estimating equations were used to consider inter-eye correlation.

Results: Following group matching, 60 eyes of 38 HPG and 103 eyes of 60 NPG patients were included. ORA measurement revealed a higher CRF in HPG than in NPG (P < 0.001). Additionally, the CST parameter integrated radius (P < 0.001) was significantly different between HPG and NPG. The parameter SSI (P < 0.001) representing corneal stiffness was higher in HPG than in NPG. Furthermore, regression analysis revealed associations between biomechanical parameters and indicators of disease severity. In HPG, SSI correlated to RNFL thickness. In NPG, dependencies between biomechanical readings and rim area, MD, and PSD were shown.

Conclusion: Significant differences in corneal biomechanical properties were detectable between HPG and NPG patients which might indicate different pathophysiological mechanisms underlying in both entities. Moreover, biomechanical parameters correlated to functional and structural indices of diseases severity. A reduced corneal deformation measured by dynamic methods was associated to advanced glaucomatous damage.

PubMed Disclaimer

Conflict of interest statement

The authors have declared that no competing interests exist.

Similar articles

Cited by

References

    1. Bowling B, Kanski JJ. Kanski’s clinical ophthalmology: a systematic approach. 8. ed. s.l.: Elsevier; 2016. 917 S. (Expert consult).
    1. Chang EE, Goldberg JL. Glaucoma 2.0: neuroprotection, neuroregeneration, neuroenhancement. Ophthalmology. Mai 2012;119(5):979–86. doi: 10.1016/j.ophtha.2011.11.003 - DOI - PMC - PubMed
    1. Leske MC, Heijl A, Hyman L, Bengtsson B, Dong L, Yang Z, u. a. Predictors of long-term progression in the early manifest glaucoma trial. Ophthalmology. November 2007;114(11):1965–72. - PubMed
    1. Bouhenni R A., Dunmire J, Sewell A, Edward DP. Animal Models of Glaucoma. J Biomed Biotechnol. 2012;2012:1–11. - PMC - PubMed
    1. Flammer J, Mozaffarieh M. What Is the Present Pathogenetic Concept of Glaucomatous Optic Neuropathy? Surv Ophthalmol. November 2007;52(6):S162–73. doi: 10.1016/j.survophthal.2007.08.012 - DOI - PubMed