Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 May;65(5):710-718.
doi: 10.1016/j.ejvs.2023.01.030. Epub 2023 Jan 24.

Additional Aortic Coverage With an Off The Shelf, Multibranched Endograft Compared With Custom Made Devices For Endovascular Repair of Pararenal Abdominal Aortic Aneurysms

Affiliations
Free article

Additional Aortic Coverage With an Off The Shelf, Multibranched Endograft Compared With Custom Made Devices For Endovascular Repair of Pararenal Abdominal Aortic Aneurysms

Paolo Spath et al. Eur J Vasc Endovasc Surg. 2023 May.
Free article

Abstract

Objective: Pararenal abdominal aortic aneurysms (p-AAA) require complex endovascular aortic repair or open surgical repair with suprarenal clamping. Custom made devices (CMD), including fenestrated and branched endovascular aortic repair (F/B-EVAR) or off the shelf (OTS) multibranched devices, are available treatment options. The aim of this study was to determine the additional healthy aortic coverage using an OTS multibranched endograft vs. a CMD for the treatment of p-AAAs.

Methods: This was a retrospective single centre analysis of prospectively collected data. Consecutive patients with p-AAAs requiring a proximal landing zone above the coeliac artery (CA), planned and treated with CMDs (Zenith Fenestrated) between January 2017 and December 2021 were included in this study. Treatment with supracoeliac coverage using available OTS multibranched devices was simulated using available pre-operative images: T-Branch; E-nside; and TAMBE. Study endpoints included the need for additional proximal aortic coverage, and the number of the segmental arteries additionally covered proximally from the CA for OTS devices compared with CMDs.

Results: Eighty three patients with p-AAAs were treated with CMDs (all FEVAR), including juxtarenal AAAs (n = 46; 56%), suprarenal AAAs (n = 20; 24%), and short neck AAAs (n = 17; 20%). In this study, treatment with 249 (3 × 83) OTS endografts was simulated. When compared with CMDs, OTS devices required a mean of 74 ± 19 mm of additional proximal healthy aortic coverage from the CA (CMD: 33 ± 19 mm vs. OTS: 108 ± 6 mm; p ≤ .001), as well as an average sacrifice of 2.5 additional segmental arteries (CMD: 1.3 ± 0.8 vs. OTS: 3.8 ± 0.9; p ≤ .001). In 94% of patients, at least one of the available multibranched endografts could have been implanted in accordance with instructions for use.

Conclusion: Despite not requiring customisation time, OTS endografts for the treatment of p-AAA lead to more extensive healthy aortic coverage, as well as an average sacrifice of 2.5 additional segmental arteries, compared with CMDs. When compared with OTS devices, CMDs appear to limit the extent of unnecessary aortic coverage and the theoretical subsequent risk of spinal cord ischaemia.

Keywords: Aortic coverage; Custom made device; Fenestrated and branched endograft; Off the shelf device; Pararenal abdominal aortic aneurysm; Spinal cord ischaemia.