. 2023 Mar;16(1):102-108.
doi: 10.1007/s12194-023-00702-9. Epub 2023 Jan 31.

Monte Carlo simulation study to explore optimum conditions for Astatine-211 SPECT

Affiliations

Monte Carlo simulation study to explore optimum conditions for Astatine-211 SPECT

Akihiko Takahashi et al. Radiol Phys Technol. 2023 Mar.

Abstract

211At is a promising nuclide for targeted radioisotope therapy. Direct imaging of this nuclide is important for in vivo evaluation of its distribution. We investigated suitable conditions for single-photon emission computed tomography (SPECT) imaging of 211At and assessed their feasibility using a homemade Monte Carlo simulation code, MCEP-SPECT. Radioactivity concentrations of 5, 10, or 20 kBq/mL were distributed in six spheres in a National Electrical Manufactures Association (NEMA) body phantom with a background of 1 kBq/mL. The energy window, projection number, and acquisition time were 71-88 keV, 60, and 60 s, respectively, per projection. A medium-energy collimator and three low-energy collimators were tested. SPECT images were reconstructed using the ordered subset expectation maximization (OSEM) method with attenuation correction (Chang method) and scatter correction (triple-energy-windows method). Image quality was evaluated using the contrast-to-noise ratio (CNR) for detectability and the contrast recovery coefficient (CRC) for quantitavity. The low-energy, high-sensitivity collimator exhibited the best detectability among the four types of collimators, with a maximum CNR value of 43. In contrast, the low-energy, high-resolution collimator exhibited excellent quantitavity, with a maximum CRC value of 102%. Scatter correction improved the image quality. In particular, the CRC value almost doubled after scatter correction. The detection of spheres smaller than 20 mm in diameter was difficult. In summary, low-energy collimators were suitable for the SPECT imaging of 211At. In addition, scatter correction was extremely effective in improving the image quality. The feasibility of 211At SPECT was demonstrated for lesions larger than 20 mm.

Keywords: Astatine-211; SPECT; Targeted alpha-particle therapy; Thyroid cancer.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Zalutsky MR, Reardon DA, Akabani G, Coleman R, Friedman AH, Friedman HS, et al. Clinical experience with a-particle–emitting 211At: Treatment of recurrent brain tumor patients with 211At-labeled chimeric antitenascin monoclonal antibody 81C6. J Nucl Med. 2008;49:30–8. - DOI - PubMed
    1. Palm S, Bäck T, Aneheima E, Hallqvist A, Hultborn R, Jacobsson L, et al. Evaluation of therapeutic efficacy of 211At-labeled farletuzumab in an intraperitoneal mouse model of disseminated ovarian cancer. Trans Oncol. 2021;14: 100873. - DOI
    1. Watabe T, Nakashima KK, Liu Y, Shirakami Y, Ooe K, Toyoshima A, et al. Enhancement of 211At uptake via the sodium iodide symporter by the addition of ascorbic acid in targeted a-therapy of thyroid cancer. J Nucl Med. 2019;60:1301–7. - DOI - PubMed
    1. Poty S, Francesconi LC, McDevitt MR, Morris MJ, Lewis JS. α-emitters for radiotherapy: from basic radiochemistry to clinical studies—Part 1. J Nucl Med. 2018;59:878–84. - DOI - PubMed
    1. Poty S, Francesconi LC, McDevitt MR, Morris MJ, Lewis JS. α-emitters for radiotherapy: from basic radiochemistry to clinical studies—Part 2. J Nucl Med. 2018;59:1020–6. - DOI - PubMed

MeSH terms

LinkOut - more resources