Investigating the Link Between Visual Quality and Vision-Related Quality of Life in Patients With Keratoconus
- PMID: 36729659
- DOI: 10.1097/ICO.0000000000003200
Investigating the Link Between Visual Quality and Vision-Related Quality of Life in Patients With Keratoconus
Abstract
Purpose: The purpose of the study was to investigate the optical and visual determinants of vision-related quality of life (VR-QoL) in patients with keratoconus.
Methods: A cross-sectional case-control study was conducted at the Department of Ophthalmology, Antwerp University Hospital, Belgium. Patients previously diagnosed with keratoconus and healthy emmetropic or ametropic volunteers were included. Patients younger than 18 years, with ametropia of more than ±10 D, or with a history of corneal surgery or relevant ocular comorbidity limiting visual acuity were excluded. Assessment included autorefraction, high-contrast visual acuity testing, corneal imaging, intraocular straylight analysis, contrast sensitivity, aberrometry, and the National Eye Institute Visual Functioning Questionnaire (NEI VFQ-25). The Rasch-modified visual functioning scale (VFS) and socio-emotional scale were used to quantify VR-QoL. Stepwise linear regression was used to investigate the association between the clinical variables and VR-QoL.
Results: Seventy-seven patients with keratoconus (77 pairs of eyes) and 77 age-matched and sex-matched controls were included in the study. The scores on the VFS and the SES were significantly lower in patients with keratoconus compared with controls ( P < 0.001). Higher-order and lower-order aberrations, high-contrast visual acuity, and contrast sensitivity were poorer in patients with keratoconus ( P < 0.001). Bivariate analyses showed that spectacle-corrected high-contrast visual acuity, higher spatial frequency contrast sensitivity, and higher-order aberration metrics were strong predictors of SES ( P < 0.001) and of VFS ( P < 0.001). Higher-order aberration of the worse eye was the strongest predictor for both SES (b = 0.310, P < 0.001) and VFS (b = 0.638, P < 0.001) on stepwise regression. Contrast sensitivity was not included in the stepwise regression because of insufficient data in the keratoconus group (33/77 patients; 42.9%).
Conclusions: Both higher and lower aberration showed a strong correlation with VR-QoL, surpassing high-contrast visual acuity. These findings underline the importance of visual quality measures within keratoconus research and clinical care.
Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.
Conflict of interest statement
The authors have no funding or conflicts of interest to disclose.
References
-
- Kymes SM, Walline JJ, Zadnik K, et al. Collaborative longitudinal evaluation of keratoconus study: quality of life in keratoconus. Am J Ophthalmol. 2004;138:527–535.
-
- Godefrooij DA, de Wit GA, Uiterwaal CS, et al. Age-specific Incidence and prevalence of keratoconus: a nationwide registration study. Am J Ophthalmol. 2017;175:169–172.
-
- Chan E, Chong EW, Lingham G, et al. Prevalence of keratoconus based on scheimpflug imaging: the raine study. Ophthalmology. 2021;128:515–521.
-
- Kandel H, Pesudovs K, Watson SL. Measurement of quality of life in keratoconus. Cornea 2020;39:386–393.
-
- Gothwal VK, Gujar R, Pesudovs K, et al. Factors affecting quality of life in keratoconus. Ophthalmic Physiol Opt. 2022;42:986–997.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical