Estimation with Monte Carlo of thermal neutrons in the FANT, using 252Cf and 241Am/9Be neutron source
- PMID: 36731391
- DOI: 10.1016/j.apradiso.2023.110694
Estimation with Monte Carlo of thermal neutrons in the FANT, using 252Cf and 241Am/9Be neutron source
Abstract
The thermal neutron irradiation device (FANT), developed at the Neutron Measurements Laboratory of the Energy Engineering Department at Universidad Politécnica de Madrid, is a high-density polyethylene regular parallelepiped, with a rather uniform neutron fluence inside its irradiation chamber. It uses a Am95241/Be49 neutron source aiming to provide thermal neutron fluence rates. Neutron spectra and neutron fluences were estimated with Monte Carlo methods in the FANT irradiation chamber when a Cf98252 neutron source is used and were compared with the results obtained with the Am95241/Be49 source. Regardless of the neutron source, the largest contribution is due to thermal neutrons, producing also epithermal and fast neutrons. Per neutron emitted by the source, the use of Cf98252 produces a larger amount of neutrons.
Keywords: FANT; Monte Carlo; Neutron spectra.
Copyright © 2023 Elsevier Ltd. All rights reserved.
Conflict of interest statement
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.