Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Oct 13;67(4):539-547.
doi: 10.2186/jpr.JPR_D_22_00135. Epub 2023 Feb 4.

Effect of mandibular bilateral distal extension denture design on masticatory performance

Affiliations
Free article

Effect of mandibular bilateral distal extension denture design on masticatory performance

Tasuku Yoshimoto et al. J Prosthodont Res. .
Free article

Abstract

Purpose: Removable partial dentures have a wide range of applications as missing tooth prostheses, and the denture design can be quite diverse. However, the factors affecting masticatory function remain unclear. We investigated the effect of denture design, especially the use of indirect retainers and major connectors, on masticatory function in patients with mandibular bilateral distal extension dentures.

Methods: Fifty-three patients with mandibular Kennedy Class I and Eichner classification B occlusal support were included in this study. Masticatory performance (MP) was assessed using gummy jelly. For the dentures, the type of major connector (bar or apron), presence or absence of indirect retainers, number of rests, and number of artificial teeth were evaluated. The number of functional teeth and occlusal support, Eichner classification, maxillary denture usage, mandibular residual ridge height, and duration of denture use were also evaluated. The factors influencing on the MP were evaluated using the Mann-Whitney U test, Spearman's correlation coefficient, and logistic regression analysis.

Results: MP was significantly higher when the major connector was bar-type or when there was an indirect retainer than with an apron-type or no indirect retainer. MP was positively correlated with the number of functional teeth, occlusal support, and number of rests. Logistic regression analysis revealed that the number of functional teeth and the presence or absence of an indirect retainer were factors that significantly influenced the MP.

Conclusions: An indirect retainer setting is useful for achieving good masticatory performance in mandibular bilateral distal extension dentures.

Keywords: Denture design; Denture stability; Major connector; Mastication; Removable partial denture.

PubMed Disclaimer