. 2023 Aug;143(8):4805-4812.
doi: 10.1007/s00402-023-04801-5. Epub 2023 Feb 10.

Dual plate has better biomechanical stability than hook plate or superior single plate for the fixation of unstable distal clavicle fractures: a finite element analysis

Affiliations

Dual plate has better biomechanical stability than hook plate or superior single plate for the fixation of unstable distal clavicle fractures: a finite element analysis

Daoqiang Huang et al. Arch Orthop Trauma Surg. 2023 Aug.

Abstract

Introduction: A variety of surgical techniques have been addressed for distal clavicle fractures, while none of these is considered to be gold standard fixation. Currently, dual plate fixation has been proposed and achieved satisfying clinical results. However, the biomechanical study about dual plate technique in treating unstable distal clavicle fractures is limited. Thus, the purpose of this study was to investigate the biomechanical properties of this technique by finite element analysis.

Materials and methods: A geometry model of distal clavicle fractures was combined with hook plate, superior single plate and dual plate, respectively, to simulate the implant fixation process. Two loading conditions and two boundary conditions were applied in the finite element models following a mesh convergence test. The stress distribution was observed, and peak von Mises stress and maximum displacement were used as indexes for analysis.

Results: The dual plate model showed the highest clavicle stress (13.1 MPa), but lowest fixation stress (18.9 MPa) compared to the hook plate and superior single model. In regarded to stability, dual plate model exhibited a minimum displacement with only 0.099 mm.

Conclusions: Dual plate fixation has better biomechanical stability with lower risk of implant failure. Thus, dual plate fixation is an alternative technique for unstable distal clavicle fracture. The complication of peri-implant fracture of dual plate technique should also be cautious in clinical practice, and more clinical evidence is needed.

Keywords: Biomechanics; Distal clavicle fractures; Dual plate; Finite element analysis.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Khan LA, Bradnock TJ, Scott C, Robinson CM (2009) Fractures of the clavicle. J Bone Jt Surg Am 91:447–460. https://doi.org/10.2106/jbjs.h.00034 - DOI
    1. Neer CS 2nd (1968) Fractures of the distal third of the clavicle. Clin Orthop Relat Res 58:43–50 - DOI - PubMed
    1. Ogden JA (1984) Distal clavicular physeal injury. Clin Orthop Relat Res 188:68–73 - DOI
    1. Banerjee R, Waterman B, Padalecki J, Robertson W (2011) Management of distal clavicle fractures. J Am Acad Orthop Surg 19:392–401. https://doi.org/10.5435/00124635-201107000-00002 - DOI - PubMed
    1. van der Meijden OA, Gaskill TR, Millett PJ (2012) Treatment of clavicle fractures: current concepts review. J Shoulder Elbow Surg 21:423–429. https://doi.org/10.1016/j.jse.2011.08.053 - DOI - PubMed