Inter-Examiner Disagreement for Assessing Cervical Multifidus Ultrasound Metrics Is Associated with Body Composition Features
Abstract
Ultrasound imaging (US) is a biosensing technique that is widely used in several healthcare disciplines (including physiotherapy) for assessing multiple muscle metrics, such as muscle morphology and quality. Since all biosensors need to be tested in order to demonstrate their reliability, accuracy, sensitivity, and specificity, identifying factors that affect their diagnostic accuracy is essential. Since previous studies analyzed the impact of sociodemographic but not body composition characteristics in US errors, this study aimed to assess whether body composition metrics are associated with ultrasound measurement errors. B-mode images of the lumbar multifidus muscle at the L5 level were acquired and analyzed in 47 healthy volunteers by two examiners (one experienced and one novice). The cross-sectional area, muscle perimeter, and mean echo intensity were calculated bilaterally. A correlation analysis and a multivariate linear regression model were used for assessing the inter-examiner differences with respect to body composition metrics. The results demonstrated good-to-excellent reliability estimates for the cross-sectional area, muscle perimeter, aspect ratio, roundness, circularity, and mean brightness metrics (all ICC > 0.85). However, solidity showed unacceptable reliability (ICC < 0.7). Age, height, total lean mass, trunk lean mass, and water volume were associated with inter-examiner disagreement on mean echo intensity. Cross-sectional area, perimeter, and roundness measurement errors were associated with lean mass and water volume.
Keywords: body composition; diagnostic accuracy studies; fat; lean mass; reliability; spine; ultrasound imaging.
Conflict of interest statement
The authors declare no conflict of interest.
Figures
Similar articles
-
Correlation between Body Composition and Inter-Examiner Errors for Assessing Lumbar Multifidus Muscle Size, Shape and Quality Metrics with Ultrasound Imaging.Bioengineering (Basel). 2023 Jan 18;10(2):133. doi: 10.3390/bioengineering10020133. Bioengineering (Basel). 2023. PMID: 36829627 Free PMC article.
-
Echo-intensity and fatty infiltration ultrasound imaging measurement of cervical multifidus and short rotators in healthy people: A reliability study.Musculoskelet Sci Pract. 2021 Jun;53:102335. doi: 10.1016/j.msksp.2021.102335. Epub 2021 Jan 23. Musculoskelet Sci Pract. 2021. PMID: 33531271
-
A Procedure for Measuring Anterior Scalene Morphology and Quality with Ultrasound Imaging: An Intra- and Inter-rater Reliability Study.Ultrasound Med Biol. 2023 Aug;49(8):1817-1823. doi: 10.1016/j.ultrasmedbio.2023.04.005. Epub 2023 May 13. Ultrasound Med Biol. 2023. PMID: 37188569
-
Reliability of Real-time Ultrasound Imaging for the Assessment of Trunk Stabilizer Muscles: A Systematic Review of the Literature.J Ultrasound Med. 2019 Jan;38(1):15-26. doi: 10.1002/jum.14661. Epub 2018 Apr 24. J Ultrasound Med. 2019. PMID: 29688574
-
Relationships between paraspinal muscle morphology and neurocompressive conditions of the lumbar spine: a systematic review with meta-analysis.BMC Musculoskelet Disord. 2018 Sep 27;19(1):351. doi: 10.1186/s12891-018-2266-5. BMC Musculoskelet Disord. 2018. PMID: 30261870 Free PMC article.
Cited by
-
Cervical Multifidus Stiffness Assessment in Individuals with and without Unilateral Chronic Neck Pain: An Inter-Examiner Reliability Study.Bioengineering (Basel). 2024 May 16;11(5):500. doi: 10.3390/bioengineering11050500. Bioengineering (Basel). 2024. PMID: 38790366 Free PMC article.
-
Levator Scapulae Stiffness Measurement Reliability in Individuals with and without Chronic Neck Pain by Experienced and Novel Examiners.Sensors (Basel). 2024 Jan 3;24(1):277. doi: 10.3390/s24010277. Sensors (Basel). 2024. PMID: 38203140 Free PMC article.
-
Convergent Validity between Electromyographic Muscle Activity, Ultrasound Muscle Thickness and Dynamometric Force Measurement for Assessing Muscle.Sensors (Basel). 2023 Feb 10;23(4):2030. doi: 10.3390/s23042030. Sensors (Basel). 2023. PMID: 36850629 Free PMC article.
-
Body Composition and Demographic Features Do Not Affect the Diagnostic Accuracy of Shear Wave Elastography.Bioengineering (Basel). 2023 Jul 30;10(8):904. doi: 10.3390/bioengineering10080904. Bioengineering (Basel). 2023. PMID: 37627789 Free PMC article.
-
Measurement Reliability for the Anatomical Characteristics of Cervical Muscles Using Musculoskeletal Ultrasound in Healthy Individuals.Muscles. 2025 Aug 5;4(3):28. doi: 10.3390/muscles4030028. Muscles. 2025. PMID: 40843915 Free PMC article.
References
-
- Arimi S.A., Bandpei M.A.M., Rezasoltani A., Peolsson A., Mohammadi M. Multifidus muscle size changes at different directions of head and neck movements in females with unilateral chronic non-specific neck pain and healthy subjects using ultrasonography. J. Bodyw. Mov. Ther. 2018;22:560–565. doi: 10.1016/j.jbmt.2017.09.011. - DOI - PubMed
-
- Mitsutake T.M., Sakamoto M., Chyuda Y., Oka S.M., Hirata H.M., Matsuo T.M., Oishi T., Horikawa E. Greater Cervical Muscle Fat Infiltration Evaluated by Magnetic Resonance Imaging is Associated with Poor Postural Stability in Patients with Cervical Spondylotic Radiculopathy. Spine. 2016;41:E8–E14. doi: 10.1097/BRS.0000000000001196. - DOI - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources