Inter-Examiner Disagreement for Assessing Cervical Multifidus Ultrasound Metrics Is Associated with Body Composition Features
- PMID: 36772252
- PMCID: PMC9921918
- DOI: 10.3390/s23031213
Inter-Examiner Disagreement for Assessing Cervical Multifidus Ultrasound Metrics Is Associated with Body Composition Features
Abstract
Ultrasound imaging (US) is a biosensing technique that is widely used in several healthcare disciplines (including physiotherapy) for assessing multiple muscle metrics, such as muscle morphology and quality. Since all biosensors need to be tested in order to demonstrate their reliability, accuracy, sensitivity, and specificity, identifying factors that affect their diagnostic accuracy is essential. Since previous studies analyzed the impact of sociodemographic but not body composition characteristics in US errors, this study aimed to assess whether body composition metrics are associated with ultrasound measurement errors. B-mode images of the lumbar multifidus muscle at the L5 level were acquired and analyzed in 47 healthy volunteers by two examiners (one experienced and one novice). The cross-sectional area, muscle perimeter, and mean echo intensity were calculated bilaterally. A correlation analysis and a multivariate linear regression model were used for assessing the inter-examiner differences with respect to body composition metrics. The results demonstrated good-to-excellent reliability estimates for the cross-sectional area, muscle perimeter, aspect ratio, roundness, circularity, and mean brightness metrics (all ICC > 0.85). However, solidity showed unacceptable reliability (ICC < 0.7). Age, height, total lean mass, trunk lean mass, and water volume were associated with inter-examiner disagreement on mean echo intensity. Cross-sectional area, perimeter, and roundness measurement errors were associated with lean mass and water volume.
Keywords: body composition; diagnostic accuracy studies; fat; lean mass; reliability; spine; ultrasound imaging.
Conflict of interest statement
The authors declare no conflict of interest.
Figures
References
-
- Arimi S.A., Bandpei M.A.M., Rezasoltani A., Peolsson A., Mohammadi M. Multifidus muscle size changes at different directions of head and neck movements in females with unilateral chronic non-specific neck pain and healthy subjects using ultrasonography. J. Bodyw. Mov. Ther. 2018;22:560–565. doi: 10.1016/j.jbmt.2017.09.011. - DOI - PubMed
-
- Mitsutake T.M., Sakamoto M., Chyuda Y., Oka S.M., Hirata H.M., Matsuo T.M., Oishi T., Horikawa E. Greater Cervical Muscle Fat Infiltration Evaluated by Magnetic Resonance Imaging is Associated with Poor Postural Stability in Patients with Cervical Spondylotic Radiculopathy. Spine. 2016;41:E8–E14. doi: 10.1097/BRS.0000000000001196. - DOI - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources