Evaluating clinical accuracy of systems for self-monitoring of blood glucose
- PMID: 3677983
- DOI: 10.2337/diacare.10.5.622
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Abstract
Although the scientific literature contains numerous reports of the statistical accuracy of systems for self-monitoring of blood glucose (SMBG), most of these studies determine accuracy in ways that may not be clinically useful. We have developed an error grid analysis (EGA), which describes the clinical accuracy of SMBG systems over the entire range of blood glucose values, taking into account 1) the absolute value of the system-generated glucose value, 2) the absolute value of the reference blood glucose value, 3) the relative difference between these two values, and 4) the clinical significance of this difference. The EGA of accuracy of five different reflectance meters (Eyetone, Dextrometer, Glucometer I, Glucometer II, Memory Glucometer II), a visually interpretable glucose reagent strip (Glucostix), and filter-paper spot glucose determinations is presented. In addition, reanalyses of a laboratory comparison of three reflectance meters (Accucheck II, Glucometer II, Glucoscan 9000) and of two previously published studies comparing the accuracy of five different reflectance meters with EGA is described. EGA provides the practitioner and the researcher with a clinically meaningful method for evaluating the accuracy of blood glucose values generated with various monitoring systems and for analyzing the clinical implications of previously published data.
Similar articles
-
Evaluation of a new system for self blood glucose monitoring.Diabetes Res Clin Pract. 1988 Feb 19;4(3):209-13. doi: 10.1016/s0168-8227(88)80020-2. Diabetes Res Clin Pract. 1988. PMID: 3359921
-
Self glucose monitoring: a comparison of the Glucometer, Glucoscan, and Hypocount B.Diabetes Care. 1983 May-Jun;6(3):262-7. doi: 10.2337/diacare.6.3.262. Diabetes Care. 1983. PMID: 6347579
-
Evaluation of two reagent strips and three reflectance meters for rapid determination of blood glucose concentrations.J Vet Intern Med. 1987 Oct-Dec;1(4):170-4. doi: 10.1111/j.1939-1676.1987.tb02011.x. J Vet Intern Med. 1987. PMID: 3506102
-
Evaluating clinical accuracy of continuous glucose monitoring systems: Continuous Glucose-Error Grid Analysis (CG-EGA).Curr Diabetes Rev. 2008 Aug;4(3):193-9. doi: 10.2174/157339908785294389. Curr Diabetes Rev. 2008. PMID: 18690900 Review.
-
A Perspective on the Accuracy of Blood Glucose Meters During Pregnancy.Diabetes Care. 2018 Oct;41(10):2053-2058. doi: 10.2337/dc18-0833. Diabetes Care. 2018. PMID: 30237233 Review.
Cited by
-
Continuous Glucose Deviation Interval and Variability Analysis (CG-DIVA): A Novel Approach for the Statistical Accuracy Assessment of Continuous Glucose Monitoring Systems.J Diabetes Sci Technol. 2024 Jul;18(4):857-865. doi: 10.1177/19322968221134639. Epub 2022 Nov 3. J Diabetes Sci Technol. 2024. PMID: 36329636 Free PMC article.
-
Blood glucose measurements in critically ill patients.J Diabetes Sci Technol. 2012 Jan 1;6(1):22-8. doi: 10.1177/193229681200600104. J Diabetes Sci Technol. 2012. PMID: 22401319 Free PMC article. Review.
-
Hypoglycemia and diabetes: a report of a workgroup of the American Diabetes Association and the Endocrine Society.Diabetes Care. 2013 May;36(5):1384-95. doi: 10.2337/dc12-2480. Epub 2013 Apr 15. Diabetes Care. 2013. PMID: 23589542 Free PMC article.
-
Escaping the Hemoglobin A1c-Centric World in Evaluating Diabetes Mellitus Interventions.J Diabetes Sci Technol. 2015 Feb 19;9(5):1148-51. doi: 10.1177/1932296815576363. J Diabetes Sci Technol. 2015. PMID: 25697718 Free PMC article.
-
Evaluation of the performance of a novel system for continuous glucose monitoring.J Diabetes Sci Technol. 2013 Jul 1;7(4):815-23. doi: 10.1177/193229681300700403. J Diabetes Sci Technol. 2013. PMID: 23911162 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical