Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jun;40(6):e15068.
doi: 10.1111/dme.15068. Epub 2023 Feb 25.

Associations between insulin pump self-management and HbA1c in type 1 diabetes

Affiliations

Associations between insulin pump self-management and HbA1c in type 1 diabetes

Karen Rytter et al. Diabet Med. 2023 Jun.

Abstract

Aims: Insulin pump self-management is important for glycaemic outcomes. We aimed to investigate associations between self-management factors and HbA1c.

Methods: Adult insulin pump users with type 1 diabetes (n = 770) completed an online questionnaire. The latest HbA1c and demographics were extracted from national registries. Associations between HbA1c and self-management (use of advanced features, timing of infusion set change, timing of meal bolus, data-upload and pump settings adjustments) were investigated using backward selected linear regression models.

Results: Of the 699 responders eligible for this study, 60% were women; the median age and diabetes duration were 49 and 25 years, respectively. Significant associations with HbA1c were found for changing infusion set every 0-4 days relative to 5-10 days (-5 mmol/mol (-0.4%), p = 0.003), and for never/rarely missing a bolus (-6 mmol/mol (-0.5%), p < 0.001) relative to often missing a bolus. Timing insulin 10-15 min before meal relative to after meal start was also associated with lower HbA1c (-3 mmol/mol (-0.3%), p = 0.023). Self-adjusting pump settings showed the strongest association with lower HbA1c (-6 mmol/mol (-0.6%), p < 0.001) relative to health care professionals doing all adjustments.

Conclusion: Self-adjusting insulin pump settings, optimal timing and few omissions of meal boluses, and timely change of infusion set are associated with lower HbA1c.

Trial registration: ClinicalTrials.gov NCT04311164.

Keywords: HbA1c; diabetes education; empowerment; insulin pump; self-management; type 1 diabetes.

PubMed Disclaimer

References

REFERENCES

    1. Foster NC, Beck RW, Miller KM, et al. State of type 1 diabetes management and outcomes from the T1D exchange in 2016-2018. Diabetes Technol Ther. 2019;21(2):66-72. doi:10.1089/dia.2018.0384
    1. Gajewska KA, Bennett K, Biesma R, Sreenan S. Low uptake of continuous subcutaneous insulin infusion therapy in people with type 1 diabetes in Ireland: a retrospective cross-sectional study. BMC Endocr Disord. 2020;20(1):92. doi:10.1186/s12902-020-00573-w
    1. The Swedish National Diabetes Register (NDR). Accessed August 2022. https://www.ndr.nu/#/knappen
    1. Barnard KD, Breton MD. Diabetes technological revolution: winners and losers? J Diabetes Sci Technol. 2018;12(6):1227-1230. doi:10.1177/1932296818788872
    1. Tanenbaum ML, Hanes SJ, Miller KM, Naranjo D, Bensen R, Hood KK. Diabetes device use in adults with type 1 diabetes: barriers to uptake and potential intervention targets. Diabetes Care. 2017;40(2):181-187. doi:10.2337/dc16-1536

Associated data