. 2023 Jun;34(6):1431-1440.
doi: 10.1111/jce.15862. Epub 2023 May 26.

Variation in optimal hemodynamic atrio-ventricular delay of biventricular pacing with different endocardial left ventricular lead locations using precision hemodynamics

Affiliations
Free article

Variation in optimal hemodynamic atrio-ventricular delay of biventricular pacing with different endocardial left ventricular lead locations using precision hemodynamics

Charles J T Butcher et al. J Cardiovasc Electrophysiol. 2023 Jun.
Free article

Abstract

Introduction: It is not known whether the optimal atrioventricular (AVopt ) delay varies between left ventricular (LV) pacing site during endocardial biventricular pacing (BiVP) and may therefore needs consideration.

Methods: We assessed the hemodynamic AVopt in patients with chronic heart failure undergoing endocardial LV lead implantation. AVopt was assessed during atrio-BiVP with a "roving LV lead." Up to four locations were studied: mid-lateral wall, mid-septum (or a close alternative), site of greatest hemodynamic improvement, and LV lead implant site. The AVopt was compared to a fixed AV delay of 180 ms.

Results: Seventeen patients were included (12 male, aged 66.5 ± 12.8 years, ejection fraction 26 ± 7%, 16 left bundle branch block or high percentage of right ventricular pacing [RVP], QRS duration 167 ± 27 ms). In most locations (62/63), AVopt increased systolic blood pressure during BiVP compared with RVP (relative improvement 6 mmHg, interquartile range [IQR] 4-9 mmHg). Compared to a fixed AV delay, the hemodynamic improvement at AVopt was higher (1 mmHg, IQR 0.2-2.6 mmHg, p < .001). Within most patients (16/17), we observed a difference in AVopt between pacing sites (median paced AVopt 209 ms, IQR 117-250). Within this range, the hemodynamic impact of these differences was small (median loss 0.6 mmHg, IQR 0.1-2.6 mmHg).

Conclusion: Within a patient, different endocardial LV lead locations have slightly different hemodynamic AVopt which are superior to a fixed AV delay. The hemodynamic consequence of applying an optimum from a different lead location is small.

Keywords: atrioventricuar delay; cardiac resynchronization therapy; endocardial left ventricular lead; heart failure; hemodynamic optimization.

PubMed Disclaimer

References

REFERENCES

    1. Kyriacou A, Li Kam Wa ME, Pabari PA, et al. A systematic approach to designing reliable VV optimization methodology: assessment of internal validity of echocardiographic, electrocardiographic and haemodynamic optimization of cardiac resynchronization therapy. Int J Cardiol. 2013;167(3):954-964.
    1. Sohaib SMA, Kyriacou A, Jones S, et al. Evidence that conflict regarding size of haemodynamic response to interventricular delay optimization of cardiac resynchronization therapy may arise from differences in how atrioventricular delay is kept constant. Europace. 2016;17(12):1823-1833.
    1. Derval N, Jaïs P. Optimizing hemodynamics in cardiac resynchronization therapy by left ventricular pacing site. JACC. 2010;56(10):782-783.
    1. Spragg DD, Dong J, Fetics BJ, et al. Optimal left ventricular endocardial pacing sites for cardiac resynchronization therapy in patients with ischemic cardiomyopathy. JACC. 2010;56(10):774-781.
    1. Reddy VY, Miller MA, Neuzil P, et al. Cardiac resynchronization therapy with wireless left ventricular endocardial pacing. JACC. 2017;69(17):2119-2129.

Publication types