Development and validation of an algorithm to determine the minimal factors needed for non-invasive measurement of the in vivo primary stability of cementless hip implants
- PMID: 36792236
- DOI: 10.1016/j.medengphy.2022.103932
Development and validation of an algorithm to determine the minimal factors needed for non-invasive measurement of the in vivo primary stability of cementless hip implants
Abstract
Aseptic loosening is a frequent cause for revision of endoprosthesis. X-ray examinations like Radio-Stereometry-Analysis (RSA) are among the most widely used in vivo methods for its detection. Nevertheless, this method is not used routinely because of bone marker and related radiation exposure. This work aims at creating a new in vivo concept to detect implant stability measuring micromotions without x-ray and to develop a corresponding algorithm. Based on the assumption of contactless measurement, the input parameters for the algorithm are the distances of each ultrasound sensor to the object (prosthesis and bone) and its position. First, the number of parameters necessary for a precise reconstruction and measurement of micromotions between objects had to be defined. Therefore, the algorithm has been tested with simulations of these parameters. Two experimental measurements, either using contact sensors or ultrasound, were used to prove the accuracy of the algorithm. Simulations indicate a high accuracy with three distances as initial parameters for each object. Contact measurements show precise representation of micromotion, and the contactless measurements show the possibility of detecting various materials with a high resolution. This work lays the foundations for non-invasive detection of micromotions between the implant-bone interface.
Keywords: Biomechanics; Computational model; Data acquisition; Endoprosthesis; Primary and secondary stability; Ultrasound.
Copyright © 2022 IPEM. Published by Elsevier Ltd. All rights reserved.
Conflict of interest statement
Declaration of Competing Interest None declared.
Similar articles
-
A novel micromotion measurement method to gain instructive insight into the acetabular bone-implant interface.Med Eng Phys. 2020 Dec;86:138-145. doi: 10.1016/j.medengphy.2020.11.002. Epub 2020 Nov 11. Med Eng Phys. 2020. PMID: 33261727
-
[Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].Rev Chir Orthop Reparatrice Appar Mot. 2000 Oct;86(6):590-7. Rev Chir Orthop Reparatrice Appar Mot. 2000. PMID: 11060433 French.
-
A biomechanical testing system to determine micromotion between hip implant and femur accounting for deformation of the hip implant: Assessment of the influence of rigid body assumptions on micromotions measurements.Clin Biomech (Bristol). 2017 Feb;42:70-78. doi: 10.1016/j.clinbiomech.2017.01.009. Epub 2017 Jan 16. Clin Biomech (Bristol). 2017. PMID: 28110243
-
Strontium in the bone-implant interface.Dan Med Bull. 2011 May;58(5):B4286. Dan Med Bull. 2011. PMID: 21535993 Review.
-
New Implant Introduction in Total Hip Arthroplasty Using Radiostereometric Analysis: A Cautionary Note.J Arthroplasty. 2020 Mar;35(3):643-646. doi: 10.1016/j.arth.2019.10.004. Epub 2019 Oct 8. J Arthroplasty. 2020. PMID: 31678017 Review.
Cited by
-
[Implant anchorage: In vivo and in vitro analyses : Clusters for implant anchorage and safety].Orthopadie (Heidelb). 2024 Jul;53(7):519-526. doi: 10.1007/s00132-024-04519-1. Epub 2024 Jun 3. Orthopadie (Heidelb). 2024. PMID: 38829401 Review. German.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources