A novel echocardiography method to assess upper body systemic blood flow in preterm infants and comparison with superior vena cava flow measurement
- PMID: 36795189
- PMCID: PMC10167188
- DOI: 10.1007/s00431-023-04866-9
A novel echocardiography method to assess upper body systemic blood flow in preterm infants and comparison with superior vena cava flow measurement
Abstract
To evaluate feasibility, reproducibility, and prognostic value of a new echocardiographic method to assess systemic arterial blood flow directed to the upper part of the body (UBAF, upper body arterial flow) alternative to superior vena cava flow (SVCF) measurement. We performed echocardiographic evaluations in 106 infants in the first 2 days of life to obtain SVCF, left ventricle output (LVO), UBAF, and standard parameters of patent ductus arteriosus (PDA) significance. UBAF was calculated by subtracting from LVO the aortic arch blood flow measured immediately distally to the origin of the left subclavian artery. Main outcome measures: UBAF and SVCF agreement was assessed by Bland-Altman analysis in terms of bias, limits of agreement and repeatability index. The Intraclass Correlation Coefficient was used to measure the strength of inter-rater agreement. The agreement between UBAF and SVCF was high. The Concordance Correlation Coefficient (CCC) was 0.7434. (CCC 0.7434, 95% C.I. [0.656, 0.8111]). There was a good absolute agreement between the two raters ICC = 0.747; p value < 0.0001; 95%CI [0.601; 0.845]. Adjusting for confounding factors (BW, GA, PDA) included in the model, there was a statistically significant relationship between UBAF and SVCF.
Conclusion: UBAF showed a strong agreement with the SCVF with a better reproducibility. Our data support UBAF as a potentially useful marker of cerebral perfusion in the evaluation of preterm infants.
What is known: • Low SVC (superior vena cava) flow in the neonatal period has been associated with periventricular haemorrhage and unfavourable long-term neurodevelopmental outcome. • Ultrasound measurement of flow in SVC shows relatively high inter-operator variability.
What is new: • Our study highlights how much overlap there is between upper-body arterial flow (UBAF) measurement and SCV flow measurement. UBAF is easier to perform and has a strong correlation with better reproducibility. • UBAF may replace measurement of cava flow as a method for haemodynamic monitoring of unstable preterm and asphyxiated infants.
Keywords: Neonatal hemodynamic; Preterm infants; Superior vena cava flow.
© 2023. The Author(s).
Conflict of interest statement
The authors declare that they have no competing interests.
Figures



Similar articles
-
Assessment of superior vena cava flow and cardiac output in different patterns of patent ductus arteriosus shunt.Echocardiography. 2021 Sep;38(9):1524-1533. doi: 10.1111/echo.15163. Epub 2021 Jul 26. Echocardiography. 2021. PMID: 34309068
-
Association between patent ductus arteriosus flow and home oxygen therapy in extremely preterm infants.Pediatr Res. 2024 Jul;96(1):208-215. doi: 10.1038/s41390-024-03120-8. Epub 2024 Mar 7. Pediatr Res. 2024. PMID: 38454005 Free PMC article.
-
Hemodynamic Effects on Systemic Blood Flow and Ductal Shunting Flow after Loading Dose of Intravenous Caffeine in Preterm Infants according to the Patency of Ductus Arteriosus.J Korean Med Sci. 2018 Jan 22;33(4):e25. doi: 10.3346/jkms.2018.33.e25. J Korean Med Sci. 2018. PMID: 29318792 Free PMC article.
-
Should SVC flow be a routine measure when performing targeted neonatal echocardiography? A narrative review.Pediatr Neonatol. 2024 Jul;65(4):323-327. doi: 10.1016/j.pedneo.2024.01.001. Epub 2024 Jan 28. Pediatr Neonatol. 2024. PMID: 38341334 Review.
-
Superior Vena Cava Flow in Preterm Infants and Neonatal Outcomes: A Systematic Review.Am J Perinatol. 2024 May;41(S 01):e2356-e2364. doi: 10.1055/a-2113-8621. Epub 2023 Jun 20. Am J Perinatol. 2024. PMID: 37339677
References
-
- Osborn DA, Evans N, Kluckow M. Clinical detection of low upper body blood flow in very premature infants using blood pressure, capillary refill time, and central peripheral temperature difference. Arch Dis Child Fetal Neonatal Ed. 2004;89:F168–F173. doi: 10.1136/adc.2002.023796. - DOI - PMC - PubMed