Review
. 2023:2612:225-238.
doi: 10.1007/978-1-0716-2903-1_16.

ELISA-Based Biosensors

Affiliations
Review

ELISA-Based Biosensors

Robert S Matson. Methods Mol Biol. 2023.

Abstract

Enzyme-linked immunosorbent assay (ELISA) is by definition a biosensor. However, not all immuno-biosensors involve the use of enzymes, while other biosensors incorporate ELISA as a key signaling component. In this chapter, we review the role of ELISA in signal amplification, integration with microfluidic systems, digital labeling, and electrochemical detection.

Keywords: Amperometric; Analog; Bio-recognition; Biosensor; Digital; Digital ELISA (dELISA); Digital droplet ELISA (ddELISA); Electrochemical; Electrochemiluminescence (ECL); Enzyme-labeled fluorescence (ELF); Impedance; Lab-on-a-chip (LOC); Limit of detection (LOD); Liposome; Luminol; Microfluidics; Minimal detectable dose (MDD); Potentiometric; Pre-equilibrium digital ELISA (PEdELISA); Quantum dots; Ruthenium; Transducer; Tyramide (TSA); Working electrode.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Bhalla N, Pawan P, Formisano N, Estrela P (2016) Introduction to biosensors. Essays Biochem 60:1–8. https://doi.org/10.1042/EBC20150001 - DOI - PubMed - PMC
    1. Sun S, Yang M, Kostov Y, Rasooly A (2010) ELISA-LOC: lab-on-a-chip for enzyme-linked immunodetection. Lab Chip 16:2093–2100. https://doi.org/10.1039/C003994B - DOI
    1. Thaitrong N, Charlermroj R, Himananto O et al (2013) Implementation of microfluidic sandwich ELISA for superior detection of plant pathogens. PLoS One 8(12):e83231. https://doi.org/10.1371/journal.pone.0083231 - DOI - PubMed - PMC
    1. Tecan (2012) Application note: automating ELISAs on Tecan’s Freedom EVO® using Optimiser™ technology from Siloam Biosciences. Tecan, Männedorf
    1. Kai J, Santiago N, Puntambekar A, et al (2011) The next generation microplate using power of microfluidics for femtogram/ml level sensitivity. 15th international conference on miniaturized systems for chemistry and life sciences, 2–6 October 2011, Seattle, WA, USA