Cryo-plasma FIB/SEM volume imaging of biological specimens
- PMID: 36805107
- PMCID: PMC9995114
- DOI: 10.7554/eLife.83623
Cryo-plasma FIB/SEM volume imaging of biological specimens
Abstract
Serial focussed ion beam scanning electron microscopy (FIB/SEM) enables imaging and assessment of subcellular structures on the mesoscale (10 nm to 10 µm). When applied to vitrified samples, serial FIB/SEM is also a means to target specific structures in cells and tissues while maintaining constituents' hydration shells for in situ structural biology downstream. However, the application of serial FIB/SEM imaging of non-stained cryogenic biological samples is limited due to low contrast, curtaining, and charging artefacts. We address these challenges using a cryogenic plasma FIB/SEM. We evaluated the choice of plasma ion source and imaging regimes to produce high-quality SEM images of a range of different biological samples. Using an automated workflow we produced three-dimensional volumes of bacteria, human cells, and tissue, and calculated estimates for their resolution, typically achieving 20-50 nm. Additionally, a tag-free localisation tool for regions of interest is needed to drive the application of in situ structural biology towards tissue. The combination of serial FIB/SEM with plasma-based ion sources promises a framework for targeting specific features in bulk-frozen samples (>100 µm) to produce lamellae for cryogenic electron tomography.
Keywords: HeLa cells; R. rubrum; S. cerevisiae; Vero cells; cell biology; human; mouse tissue (brain); mouse tissue (cardiac).
© 2023, Dumoux et al.
Conflict of interest statement
MD, TG, JS, EH, LP, AP, SK, NY, DF, PL, WB, JP, LW, MB, DC, CS, JN, MG No competing interests declared, RK is an employee of ThermoFisher Scientific, MD is an employee of SPT Labtech
Figures
Update of
- doi: 10.1101/2022.09.21.508877
References
-
- Begay RL, Graw SL, Sinagra G, Asimaki A, Rowland TJ, Slavov DB, Gowan K, Jones KL, Brun F, Merlo M, Miani D, Sweet M, Devaraj K, Wartchow EP, Gigli M, Puggia I, Salcedo EE, Garrity DM, Ambardekar AV, Buttrick P, Reece TB, Bristow MR, Saffitz JE, Mestroni L, Taylor MRG. Filamin C truncation mutations are associated with arrhythmogenic dilated cardiomyopathy and changes in the cell-cell adhesion structures. JACC. Clinical Electrophysiology. 2018;4:504–514. doi: 10.1016/j.jacep.2017.12.003. - DOI - PMC - PubMed
-
- Bogovic JA, Hanslovsky P, Wong A, Saalfeld S. Robust registration of calcium images by learned contrast synthesis. 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI 2016; Prague, Czech Republic. 2016. pp. 1123–1126. - DOI
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Molecular Biology Databases
