Fluorimetric Reusable Polymeric Sensor for Hydrogen Sulfide Detection
- PMID: 36806048
- DOI: 10.1007/s10895-023-03181-8
Fluorimetric Reusable Polymeric Sensor for Hydrogen Sulfide Detection
Abstract
In this study, with the help of reactive monomers, crosslinkers, and photoinitiator that detect H2S in various matrices, an H2S sensitive fluorescence sensor polymerizes under ultraviolet (UV) light was developed. To this goal, a polymeric membrane was prepared, and the characterization of the membrane was carried out with Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM) methods. Afterward, appropriate conditions were identified, the excitation wavelength was determined as 370 nm, and the emission wavelength was determined as 425 nm. It was established that the fluorescence intensity of the prepared polymeric membrane decreased in the presence of H2S. A detailed analysis was executed to determine the sensor's most suitable pH value and time. It was found that the optimum pH was 8.0, and the optimal duration was 15 s. It has been calculated that the linear range of the developed method is 2.19 × 10-8- 6.25 × 10-7 M, and the detection limit (LOD) is 7.37 × 10-9 M. The effect of some possible interfering ions was investigated, and it determined that the sensor had excellent selectivity. In addition, the sensor used to determine H2S can be used at least 100 times. The recovery percentages were 102.1%-103.2%, and 104.6%, using tap water samples. In terms of providing reliable, fast results, high sensitivity, reusable, low cost, and ease of use, the developed fluorimetric sensor, compared to standard methods, has become more advantageous.
Keywords: Fluorimetric sensor; Photo-curing; Polymeric membrane; Selective H2S determination.
© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
References
-
- Ayesh AI, Abu-Hani AFS, Mahmoud ST, Haik Y (2016) Selective H2S sensor based on CuO nanoparticles embedded in organic membranes. Sens Actuators B Chem 231:593–600. https://doi.org/10.1016/jsnb201603078 - DOI
-
- Kimura H (2013) Physiological role of hydrogen sulfide and polysulfide in the central nervous system. Neurochem Int 63:492–497. https://doi.org/10.1016/j.neuint.2013.09.003 - DOI - PubMed
-
- Barczak RJ, Możaryn J, Fisher RM, Stuetzb RM (2022) Odour concentrations prediction based on odorants concentrations from biosolid emissions. Environ Res 214:113871. https://doi.org/10.1016/j.envres.2022.113871 - DOI - PubMed
-
- Taha A, Patón M, Rodríguez J (2022) Model-based design and operation of biotrickling filters for foul air H2S removal at wastewater networks. J Environ Chem Eng 10:107372. https://doi.org/10.1016/j.jece.2022.107372 - DOI
-
- Spadaro L, Palella A, Frusteri F, Arena F (2015) Valorization of crude bio-oil to sustainable energy vector for applications in cars powering and on-board reformers via catalytic hydrogenation. Int J Hydrogen Energy 40:14507–14518. https://doi.org/10.1016/j.ijhydene.2015.08.010 - DOI
LinkOut - more resources
Full Text Sources
Miscellaneous
