MR evaluation of chronic aortic dissection
- PMID: 3680710
- DOI: 10.1097/00004728-198711000-00009
MR evaluation of chronic aortic dissection
Abstract
Thirty patients with suspected or known chronic aortic dissection were imaged with magnetic resonance (MR), CT, and angiography. Five of these patients had previously undergone surgical repair of the ascending aorta for a type A dissection. Magnetic resonance demonstrated an intimal flap and a double lumen in 25 cases. In four cases with a thrombosed false lumen, proved angiographically, an intimal flap and double channel were not seen. In two of four aortic dissections with a thrombosed false lumen, CT made the diagnosis by showing displaced intimal calcifications not visualized on MR. In one case the aortic dissection was made on CT and angiography but was not supported by MR which showed an aortic aneurysm, subsequently confirmed at surgery. Magnetic resonance, CT, and aortography differentiated between type A (nine patients) or B (20 patients) dissection in all cases and demonstrated extension into the abdominal aorta. Extension into the iliac arteries was seen on MR in three patients but missed in nine patients. Magnetic resonance differentiated the true and false lumen in all but one case. Thrombosis of the false channel was identified in four cases by a decrease in signal intensity on the second echo image. Cardiac gating and longitudinal contiguous sections seemed to be more suitable for appreciation of the relationships with arch vessels. Transverse contiguous slices allowed determination of the origin of celiac, mesenteric, and renal arteries from either the true or the false lumen. This study confirms that MR is an accurate and noninvasive method for the evaluation and follow-up of chronic aortic dissection, obviating the need for iodinated contrast media.
Similar articles
-
Aortic dissection: magnetic resonance imaging.Radiology. 1985 May;155(2):399-406. doi: 10.1148/radiology.155.2.3983390. Radiology. 1985. PMID: 3983390
-
A new method for quantification of false lumen thrombosis in aortic dissection using magnetic resonance imaging and a blood pool contrast agent.J Vasc Surg. 2011 Nov;54(5):1251-8. doi: 10.1016/j.jvs.2011.05.022. Epub 2011 Sep 9. J Vasc Surg. 2011. PMID: 21906904
-
Thoracic aortic dissections: magnetic resonance imaging.Radiology. 1985 May;155(2):407-12. doi: 10.1148/radiology.155.2.3983391. Radiology. 1985. PMID: 3983391
-
[Thoracic aortic aneurysms].Schweiz Med Wochenschr. 1984 Nov 10;114(45):1547-59. Schweiz Med Wochenschr. 1984. PMID: 6393325 Review. German.
-
[Aortic dissection without intimal laceration: a case report and review of the problem].Cardiologia. 1993 May;38(5):331-6. Cardiologia. 1993. PMID: 8402743 Review. Italian.
Cited by
-
Optimal diagnostic imaging of aortic dissection.Tex Heart Inst J. 1990;17(4):271-8. Tex Heart Inst J. 1990. PMID: 15227519 Free PMC article.
-
MRI in Chronic Aortic Dissection: A Systematic Review and Future Directions.Front Cardiovasc Med. 2015 Feb 19;2:5. doi: 10.3389/fcvm.2015.00005. eCollection 2015. Front Cardiovasc Med. 2015. PMID: 26664877 Free PMC article. Review.
-
Radiological evaluation of the ascending aorta following repair of type A dissection.Cardiovasc Intervent Radiol. 1993 Sep-Oct;16(5):293-6. doi: 10.1007/BF02629160. Cardiovasc Intervent Radiol. 1993. PMID: 8269425
-
Phase-contrast cine MR angiography detection of thoracic aortic dissection.Int J Card Imaging. 2000 Dec;16(6):461-70. doi: 10.1023/a:1010781305922. Int J Card Imaging. 2000. PMID: 11482712 Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Medical