. 2023 Feb 17;69(1):191-194.
doi: 10.1590/1806-9282.20220782. eCollection 2023.

Clinical effect of different dialyzers used in patients with kidney disease: a meta-analysis of randomized clinical trials

Affiliations

Clinical effect of different dialyzers used in patients with kidney disease: a meta-analysis of randomized clinical trials

Chuncheng Ma et al. Rev Assoc Med Bras (1992). .
No abstract available

PubMed Disclaimer

Conflict of interest statement

Conflicts of interest: the authors declare there is no conflicts of interest.

Figures

Figure 1
Figure 1. (A) Forest plot of urea nitrogen clearance. (B) Forest plot of creatinine clearance. (C) Forest plot of β2-microglobulin clearance. (D) Forest plot of phosphoric acid clearance. (E) Forest plot of hemoglobin removal rate. (F) Forest plot of myoglobin removal rate.

Similar articles

References

    1. Morti S, Shao J, Zydney AL. Importance of asymmetric structure in determining mass transport characteristics of hollow fiber hemodialyzers. J Membr Sci. 2003;224(1-2):39–49. doi: 10.1016/j.memsci.2003.06.001. - DOI
    1. Weiner DE, Falzon L, Skoufos L, Bernardo A, Beck W, Xiao M, et al. Efficacy and safety of expanded hemodialysis with the theranova 400 dialyzer: a randomized controlled trial. Clin J Am Soc Nephrol. 2020;15(9):1310–1319. doi: 10.2215/CJN.01210120. - DOI - PMC - PubMed
    1. Abe M, Hamano T, Wada A, Nakai S, Masakane I. Effect of dialyzer membrane materials on survival in chronic hemodialysis patients: results from the annual survey of the Japanese Nationwide Dialysis Registry. PLoS One. 2017;12(9):e0184424. doi: 10.1371/journal.pone.0184424. - DOI - PMC - PubMed
    1. MacLeod A, Daly C, Khan I, Vale L, Campbell M, Wallace S, et al. Comparison of cellulose, modified cellulose and synthetic membranes in the haemodialysis of patients with end-stage renal disease. Cochrane Database Syst Rev. 2001;(3):Cd003234–Cd003234. doi: 10.1002/14651858.CD003234. - DOI - PubMed
    1. Götz AK, Böger CA, Popal M, Banas B, Krämer BK. Effect of membrane flux and dialyzer biocompatibility on survival in end-stage diabetic nephropathy. Nephron Clin Pract. 2008;109(3):c154–c160. doi: 10.1159/000145459. - DOI - PubMed

MeSH terms