Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2023 Apr;57(8):1260-1288.
doi: 10.1111/ejn.15941. Epub 2023 Mar 12.

Nine decades of electrocorticography: A comparison between epidural and subdural recordings

Affiliations
Review

Nine decades of electrocorticography: A comparison between epidural and subdural recordings

Mariana P Branco et al. Eur J Neurosci. 2023 Apr.

Abstract

In recent years, electrocorticography (ECoG) has arisen as a neural signal recording tool in the development of clinically viable neural interfaces. ECoG electrodes are generally placed below the dura mater (subdural) but can also be placed on top of the dura (epidural). In deciding which of these modalities best suits long-term implants, complications and signal quality are important considerations. Conceptually, epidural placement may present a lower risk of complications as the dura is left intact but also a lower signal quality due to the dura acting as a signal attenuator. The extent to which complications and signal quality are affected by the dura, however, has been a matter of debate. To improve our understanding of the effects of the dura on complications and signal quality, we conducted a literature review. We inventorized the effect of the dura on signal quality, decodability and longevity of acute and chronic ECoG recordings in humans and non-human primates. Also, we compared the incidence and nature of serious complications in studies that employed epidural and subdural ECoG. Overall, we found that, even though epidural recordings exhibit attenuated signal amplitude over subdural recordings, particularly for high-density grids, the decodability of epidural recorded signals does not seem to be markedly affected. Additionally, we found that the nature of serious complications was comparable between epidural and subdural recordings. These results indicate that both epidural and subdural ECoG may be suited for long-term neural signal recordings, at least for current generations of clinical and high-density ECoG grids.

Keywords: brain-computer interfaces; electrocorticography; epidural; subdural.

PubMed Disclaimer

References

REFERENCES

    1. Aarnoutse, E., Leinders, S., Freudenburg, Z., van der Vijgh, B., Pels, E., Branco, M., Ramsey, N., & Vansteensel, M. (2019). Long-term home use of a fully implanted BCI for communication: Visual and auditory spelling. In Presented at the 8th Graz brain-computer interface conference. Verlag der Technischen Universität Graz. https://doi.org/10.3217/978-3-85125-682-6-56
    1. Almeida, A. N., Martinez, V., & Feindel, W. (2005). The first case of invasive EEG monitoring for the surgical treatment of epilepsy: Historical significance and context. Epilepsia, 46, 1082-1085. https://doi.org/10.1111/j.1528-1167.2005.66404.x
    1. Anumanchipalli, G. K., Chartier, J., & Chang, E. F. (2019). Speech synthesis from neural decoding of spoken sentences. Nature, 568, 493-498.
    1. Baek, D., Lee, J., Byeon, H., Choi, H., Young Kim, I., Lee, K., Jungho Pak, J., Pyo Jang, D., & Lee, S. (2014). A thin film polyimide mesh microelectrode for chronic epidural electrocorticography recording with enhanced contactability. Journal of Neural Engineering, 11, 046023.
    1. Baker, J., Bishop, W., Kellis, S., Levy, T., House, P., & Greger, B. (2009). Multi-scale recordings for neuroprosthetic control of finger movements. Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2009, 4573-4577.

Publication types

LinkOut - more resources