Abstract
Statement of problem: Providing a removable partial denture (RPD) can be a complex, time-consuming, and error-prone procedure. Computer-aided design and computer-aided manufacturing (CAD-CAM) techniques have shown promising clinical outcomes; however, the influence of manufacturing techniques on the properties of RPD components is unclear.
Purpose: The purpose of this systematic review was to determine the accuracy and mechanical properties of RPD components fabricated with conventional and digital methods.
Material and methods: This study followed the guidelines of the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA) and was registered on the international prospective register of systematic reviews (PROSPERO) database (CRD42022353993). An electronic search was conducted on PubMed/MEDLINE, Scopus, Web of Science, and the Cochrane Library in August 2022. Only in vitro studies comparing the digital with the lost-wax casting technique were included. The quality of the studies was assessed by using the methodological index for nonrandomized studies (MINORS) scale.
Results: Of the 17 selected studies, 5 evaluated the accuracy of RPD components as well as the mechanical properties, 5 studies evaluated only the component accuracy, and another 7 evaluated only the mechanical properties. The accuracy was similar regardless of the technique, with discrepancies within clinically acceptable values (50 to 426.3 μm). The surface roughness was higher for 3D-printed clasps and lower for milled clasps (P<.05). The metal alloy significantly influenced the porosity, with the highest number of pores obtained by casting for Ti clasps and by rapid prototyping for Co-Cr clasps.
Conclusions: In vitro studies showed that the digital technique provided similar accuracy to that of the conventional technique within a clinically acceptable range. The manufacturing technique influenced the mechanical properties of RPD components.
Copyright © 2023 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Similar articles
-
ACCURACY OF REMOVABLE PARTIAL DENTURE METAL FRAMEWORKS FABRICATED BY COMPUTER-AIDED DESIGN/ COMPUTER-AIDED MANUFACTURING METHOD: A SYSTEMATIC REVIEW AND META-ANALYSIS.J Evid Based Dent Pract. 2022 Sep;22(3):101681. doi: 10.1016/j.jebdp.2021.101681. Epub 2021 Dec 3. J Evid Based Dent Pract. 2022. PMID: 36162896
-
Computer-aided technology for fabricating removable partial denture frameworks: A systematic review and meta-analysis.J Prosthet Dent. 2022 Sep;128(3):331-340. doi: 10.1016/j.prosdent.2020.06.006. Epub 2021 Feb 11. J Prosthet Dent. 2022. PMID: 33581866
-
Influence of fabrication method on the manufacturing accuracy and internal discrepancy of removable partial dentures: A systematic review and meta-analysis.J Prosthet Dent. 2025 Mar;133(3):724-735. doi: 10.1016/j.prosdent.2023.04.004. Epub 2023 Jul 18. J Prosthet Dent. 2025. PMID: 37474386
-
Final-impression techniques and materials for making complete and removable partial dentures.Cochrane Database Syst Rev. 2018 Apr 4;4(4):CD012256. doi: 10.1002/14651858.CD012256.pub2. Cochrane Database Syst Rev. 2018. PMID: 29617037 Free PMC article.
-
Accurate analysis of titanium and PolyEtherEtherKetone materials as an alternative to cobalt-chrome framework in removable partial denture: A systematic review.Dent Mater. 2024 Nov;40(11):1854-1861. doi: 10.1016/j.dental.2024.07.036. Epub 2024 Aug 27. Dent Mater. 2024. PMID: 39191558
Cited by
-
Digital versus conventional surveying for partially edentulous arches: an evaluation of accuracy and time efficiency.J Adv Prosthodont. 2025 Jun;17(3):115-124. doi: 10.4047/jap.2025.17.3.115. Epub 2025 Jun 25. J Adv Prosthodont. 2025. PMID: 40687191 Free PMC article.
-
Accuracy of Mandibular Removable Partial Denture Frameworks Fabricated by 3D Printing and Conventional Techniques.Materials (Basel). 2024 Jun 27;17(13):3148. doi: 10.3390/ma17133148. Materials (Basel). 2024. PMID: 38998231 Free PMC article.
-
In vivo study of intraoral scanner trueness in partial edentulism.Sci Rep. 2025 Jul 1;15(1):20637. doi: 10.1038/s41598-025-06562-0. Sci Rep. 2025. PMID: 40594477 Free PMC article.
-
Optimization of Bond Strength Between Heat-Polymerized PMMA and Contemporary CAD/CAM Framework Materials: A Comparative In Vitro Study.Polymers (Basel). 2025 May 27;17(11):1488. doi: 10.3390/polym17111488. Polymers (Basel). 2025. PMID: 40508730 Free PMC article.
-
Suitability and Trueness of the Removable Partial Denture Framework Fabricating by Polyether Ether Ketone with CAD-CAM Technology.Polymers (Basel). 2024 Apr 17;16(8):1119. doi: 10.3390/polym16081119. Polymers (Basel). 2024. PMID: 38675038 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous